Once these cables are in place, the LEDs on the front of the AP should
be functioning. This completes the setup. There is no need, if you are
setting this device up for use with the AirWave AMP system, for any
further setup of internal management screens.
Alternate Wiring for AC Current Use
1. Unhook the internal black power cable from the power outlet. This
cable is used only with PoE, to capture and pass along the current re-
ceived from the Power Hub.
2. Remove the short Ethernet cable which runs between the WAN and
TO WAN outlets.
Chapter 2: Set Up Procedure
7