Replacing carbon Brushes
NOTE: The Breaker Hammer will cease operation
once carbon Brushes are worn.
check Brushes every 100 hours of use
of use and replace when necessary.
1. Unplug the Breaker Hammer.
2. Set the Breaker Hammer down on a work
bench with the spline axles closer to the
top. Remove the four Bolts (97) fastening
Cover (96) in place. See Figure H.
Bolts (97)
cover (96)
Figure H
3. Slide Cover off top of Breaker
Hammer. See Figure I.
Figure I
4. Use a Wrench to loosen the Nut (40) holding
the Left Handle (82) in place. See Figure J.
Left Handle
(82)
Figure J
Page 14
cover (96)
Nut (40)
For technical questions, please call 1-888-866-5797.
NOTIcE: When removing Left Handle, do not
pull too far from Spline Axle (91) Only wiggle
loose until partially off. See Figure K.
Figure K
5. Remove the four Bolts (5) from the side
of the Gearbox (86). See Figure L.
Gearbox (86)
Figure L
6. Slide Gearbox open so that Wire Board (13)
is visible. Remove Bolt (12) from Wire
Fixing Board. See Figure M.
Bolt (12)
Figure M
Spline
Axle (91)
Left
Handle
(82)
Bolts (5)