Remote Terminal Equivalent Circuit - FOR-A IVS-200 Operation Manual

Video stabilizer
Table of Contents

Advertisement

7-1-1. Remote Terminal Equivalent Circuit

Example of connection with Remote output circuit
*1) Use protective resistance at the proper value according to the internal/external supply
voltage and LED characteristics. The current for each circuit must be kept below 30mA.
Example of connection with Remote input circuit
Inside the IVS-200
+5V
MAX 500mA
Inside IVS-200
6-7PIN
9PIN
42
Select internal or external
power supply.
1PIN
2,3,5PIN
9PIN
(External power supply)
Inside the
control device
(*1)
DC5V-24V