Tools Recommended To Troubleshoot Heaters - Re-Verber-Ray DX Troubleshooting Manual

Tube heater
Table of Contents

Advertisement

-Digital Multimeter
(Part 1A783 from Grainger)
-Flame Rectification Meter
(Channel Products)
-Digital Manometer Kit
(Part 100281-21 from Dwyer Instruments)
-Liquid Manometer Kit
(Part 115010-00 from Dwyer Instruments)
-Digital Hygro-Thermometer
(Part 1P124 from Grainger)
-Incline Manometer
(Cat# 172 from Dwyer Instruments)
-1/4" Nut Driver
- Can be used to remove screws holding top on.
(Part 5X509 from Grainger)
-Pliers 8"
- Tool for burner box access.
(Part 6C183 from Grainger)
-Pipe Wrench 8"
- Can be used to disassemble gas train assembly.
(Part 4A497 from Grainger)
-Ratcheting Box Wrench
(Part 1AMW9 from Grainger)
-6" Steel Rule
- Used for measuring air orifice size.
(Part 6C289 from Grainger)
-Terminals 1/4" Female
-Barb Fitting
- Fitting to take gas pressure at the valve.
-Vinyl Tubing
- Tubing for pressure measurements. (size 5/16" x 3')
-Jumpers/Connectors
-Self Tapping Screws
-Drill Bits 1-60, A-Z
-Manuals
- DX, DX-2 or XTS Series Installation, Operation & Maintenance manuals (IOM's).

Tools Recommended to Troubleshoot Heaters

- Used for troubleshooting & testing electrical circuits.
- Used for testing rectification of flame with the digital multimeter.
- Used for taking gas pressure, digitally.
- Used for taking gas pressure, via a liquid manometer.
(
Amprobe #TH-2)
- Used for measuring pressure inside burner box. Provides data for pressure switch.
- Can be used to remove orifice and bolts. (size 7/16" and 3/8")
- Extra female spade terminals.
- Used to jump out the pressure switches.
- Extra Screws.
- Drill Bits 1-60, A-Z, for measuring gas orifice size (DMS).
- Reads temperature from -10 to 50
1
O
C and relative humidity from 5-95%.