Optional Postal Lock; Optional Color Cctv Camera - Linear AE-100 Installation And Programming Instructions

Commercial telephone entry system
Table of Contents

Advertisement

Optional Postal Lock

A postal lock can be installed in the AE-100 Entry System to provide
keyed access for the postal service. The AE-100 case is designed to
accept a U.S. Postal Service postal lock. When the postal lock is engaged
the access relay will activate.
Postal Lock Installation
1. Remove the four locknuts that retain the postal lock cover plate
and block (above the speaker on the AE-100 faceplate).
2. Remove the cover plate and block from the
four studs. Discard the plate and block.
3. Remove the faceplate's postal lock hole plug. Discard the plug.
4. Install the postal lock assembly onto the four
studs. The postal lock's moving plunger should
point towards the microswitch (see fi gure).
5. Secure the postal lock with the four locknuts.
✦ NOTE: Be sure the postal lock's plunger actuates the microswitch.
Adjust the postal lock and test the action until the microswitch fully
actuates.
6. Tighten the four locknuts after the adjustment
and testing is complete.

Optional Color CCTV Camera

Linear's Model CCM-1 (P/N ACP00904) CCTV camera can be installed
inside the AE-100 Entry System. The camera provides a video signal for
viewing the area in front of the entry system.
The CAMERA connector is used to connect the camera to the AE-100.
The 4-conductor cable routes power to, and video from the camera.
The VIDEO OUT jack is the camera output for connection to a video
cable with a Type "BNC" connector. Up to 400 feet of 75-ohm RG-59
video cable can be used. Longer cable runs may require the use of a
video amplifi er.
✦ NOTE: The composite video signal can be viewed on a video
monitor. Alternately, a Linear ChannelPlus brand video modulator
can be used to convert the video signal to an RF signal for
installations where the camera's picture will be viewed on television
sets tuned to a custom channel.
Camera Installation
1. Remove the two locknuts and the cover plate from the camera
mounting studs on the AE-100 faceplate. Discard the cover plate.
✦ NOTE: A spare camera protection lens is supplied with the CCM-1
camera kit. If the AE-100's protection lens needs replacing due to
vandalism, push the damaged protection lens out of the faceplate
and install the spare protection lens before installing the camera.
2. Mount the camera assembly on the two studs, with
the alignment hole in the camera bracket towards the
top. Secure the camera with the two locknuts.
3. Connect the camera's cable to the AE-100's CAMERA connector.
4. Connect the video cable to the AE-100's VIDEO OUT connector.
5. Connect the other end of the video cable to the viewing monitor,
ChannelPlus brand video modulator, or video distribution system.
12
1
REMOVE LOCKNUTS
INSTALL POSTAL LOCK
3
PLUNGER POINTS
TO MICROSWITCH
NOTE: BE SURE THE POSTAL LOCK'S PLUNGER ACTUATES THE
MICROSWITCH. ADJUST THE POSTAL LOCK MOUNTING THEN
TEST THE ACTION UNTIL THE MICROSWITCH FULLY ACTUATES
1 REMOVE PLATE RETAINING NUTS
3
REMOVE THE LENS CAP
CONNECT WIRING HARNESS
5
TO CAMERA CONNECTOR
DRESS WIRES
WITH WIRE
TIES
2
REMOVE PLATE & PLUG
REPLACE LOCKNUTS
4
INSPECT MICROSWITCH ACTION
2 REMOVE THE PLATE
CAMERA
PROTECTION
LENS
4
ATTACH CAMERA WITH TWO NUTS
ALIGNMENT
HOLE
CONNECT VIDEO CABLE TO
6
VIDEO OUT CONNECTOR

Advertisement

Table of Contents
loading

Table of Contents