Chapter Three • LD-V8000 Level II
Level II code can be entered into the player's RAM with the RCU by using either the
Direct Code Entry method or the Hex Code Entry method, as described below:
• Direct Code Entry:
This is the one-button press method usually used for entering the
command codes which have a single RCU button assigned to
them (except Play). Using these convenient one-press entries, the
user can enter most arguments and the most commonly used
commands with just the RCU's numeric and command keys. The
RCU buttons other than REJECT, PLAY, PROGRAM, and END can
be used for one button-press entries. If the PROGRAM button is
pressed, new data is not written into the current byte - the old
value is retained and the next byte of the program memory is
displayed.
Example #1: Use the Direct Code Entry method. At program address 100, enter
the following program:
250 Search, 350 Auto Stop, Halt
To enter and run the program use the following sequence of RCU button presses:
100
PROGRAM
250
SEARCH
350
AUTOSTOP
HALT
END
100
RUN
3-4
TP 114 v. 1.1
Start entering code at program location 100.
Search to frame 250.
Play to frame 350.
Stops execution of Level II program.
Exits programming mode.
The player will begin to execute the program code at
program address 100.
Pioneer LD-V8000 Level II User's Manual