Samsung RB215LASH Service Manual page 61

Hide thumbs Also See for RB215LASH:
Table of Contents

Advertisement

Diagnostics
2) When R-Room FAN(R-FAN)does not operate
Freezer Door Switch input #43
Start
Is it during
Forced Operation?
YES
Does Fan
operate with DOOR
S/W presses?(Including
Delay Time)
NO
Is the
R-Room temperature a
Fan-On condition?
YES
Is DOOR S/W normal?
YES
Is the
voltage of MICOM #43 5V
(Close condition)?
YES
Is insertion of
CN71(W/BLUE)of MAIN
PCB normal?
YES
Is voltage
of MICOM Pin #30
"HIGH"(5V)?
YES
Is voltage
of IC70 #17
"LOW"(0.7V)?
YES
Is R-FAN RELAY
(SSR72) normal?
Check wire assembled status/
Change MAIN PCB AASS'Y
61
NO
Start Forced Operation
YES
Normal R-FAN
NO
Check temp conditions,
Select Super Cool
NO
Change DOOR S/W
NO
Check soldering /Change PCB
NO
Re-insert ConnectorCN71
NO
Check soldering /Change PCB
NO
Check IC70 /Change PCB
NO
Check RELAY /Change PCB