Chapter 5 Input/Output Interfaces
Reportable RSA events are listed in the following table:
Table 5–28. Remote System Alert Events
Event
BIOS Failure
Thermal Condition
Chassis Intrusion [1]
Heartbeat
NOTE:
[1] Not supported on Configurable Minitower models.
The current Remote System Alert implementation requirements are as follows:
1. 3Com Etherlink 3C905C-TX NIC.
2. 7-pin AOL/SOS cable.
3. 3Com EtherDisk Driver 5.x or later (available from Compaq).
4. Client-side utility software (included with driver).
5. Server-side utility software (called 3Com Remote System Alert Manager on the compaq.com
web site ).
6. Management console running one of the following:
a.
HP OpenView Network Node Manager 6.x
b. Microsoft Systems Management Server (SMS), version 1.2
5-38 Compaq Deskpro and Evo Personal Computers
Featuring Intel Celeron and Pentium III Processors
Table 5-28.
Remote System Alert Events
Description
System fails to boot successfully.
Thermal ASIC reports high temperature. Some systems may generate an
alert message when increasing fan speed.
Smart Cover Sensor detected cover removal. This event is battery backed,
meaning that should the unit be unplugged (from AC power) during cover
removal, notification will occur after AC power is restored.
Indication of system's network presence (sent approximately every 30
seconds in normal operation).