P/N 126773-01 Rev. A 1/2014
P126733-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
Sentinel36TEN
C
US
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Une barrière conçue pour réduire le risque de brûlure
par le hublot chaude est fournie avec l'appareil et doit
être installé.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Direct-Vent Gas Fireplace
Sentinel36TEP
Sentinel42TEN
Sentinel42TEP
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sentinel36TEN and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Sentinel36TEN

  • Page 1 Installation and Operation Instructions Astria Direct-Vent Gas Fireplace P/N 126773-01 Rev. A 1/2014 Models ® Sentinel36TEN Sentinel36TEP Sentinel42TEN Sentinel42TEP P126733-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more www.Astria.US.com 126733-01A...
  • Page 3 To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces www.Astria.US.com 126733-01A...
  • Page 4 11. Do not operate fireplace with glass door the fire department. removed, cracked or broken. 3. Never install the fireplace 12. Provide adequate clearances around air • in a recreational vehicle openings. • in windy or drafty areas where curtains or www.Astria.US.com 126733-01A...
  • Page 5: Local Codes

    10-20 minutes of operating very carefully for either vertical or horizontal time before the flame pattern stabilizes. applications. • This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed. www.Astria.US.com 126733-01A...
  • Page 6: Pre-Installation

    • Do not locate termination cap and outside (42" MODEL) 11.50" air vent where excessive snow or ice build up may occur. Be sure to clear vent ter- Figure 4 - Electrical Outlet and Gas mination area after snow falls to prevent Knockout Locations www.Astria.US.com 126733-01A...
  • Page 7 Note: Noncombustible mantels may discolor! Mantel Mantel from Ref. Depth Ref. Top of Opening 14" 16" 12" 14" 10" 12" 8" 10" 6" 8" 4" 6" 2" 4" Figure 7 - Clearances for Combustible Mantels www.Astria.US.com 126733-01A...
  • Page 8: Location Of Termination Cap

    Noncombustible Combustible - 6" (15.2 cm) H = 24" (61 cm) G = 12" (30.5 cm) minimum clearance Noncombustible - 2" (5.1 cm) J = 20" (50.8 cm) Figure 8 - Minimum Clearances for Termination Cap www.Astria.US.com 126733-01A...
  • Page 9: Requirements For The Commonwealth Of Massachusetts

    1/2" in shall remain with the appliance or equipment size, "GAS VENT DIRECTLY BELOW. KEEP at the completion of the installation. CLEAR OF ALL OBSTRUCTIONS". www.Astria.US.com 126733-01A...
  • Page 10: Venting Installation

    1" air space before attempting installation. clearance is required. Failure to do so could result in serious injury, property damage or loss of life. NOTICE: Failure to follow these instructions will void the warranty. www.Astria.US.com 126733-01A...
  • Page 11: Venting Installation

    Mark wall for an 11 " x 11 " square hole. Cut and frame square hole in exterior wall where vent will be terminated. If wall being pen- Figure 10 - Vent Opening Requirements www.Astria.US.com 126733-01A...
  • Page 12 Outside " x 11 " Edge of Framed Opening Standoff Exterior Wall with Vinyl Siding Figure 14 - Typical Horizontal Termination Figure 11 - Installing Horizontal Vent Cap Cap Mounting with Additional Siding (Noncombustible Exterior) Standoff Installed www.Astria.US.com 126733-01A...
  • Page 13 3 ft. 33" 2 ft. 7 ft. 45" 3 ft. 11 ft. 57" 4 ft. 20 ft. V + H = 40 feet maximum H = 20 feet maximum Figure 15 - Horizontal Termination Using One 90° Elbow www.Astria.US.com 126733-01A...
  • Page 14 3. Drop a plumb line from inside of roof to Ceiling Firestop locating hole in ceiling. Mark center point where vent will penetrate roof. Drill a small Figure 17 - Offset with Wall Strap and 45° locating hole at this point. Elbows www.Astria.US.com 126733-01A...
  • Page 15 Figure 8 on page 8. Note: You must increase vent height for Figure 18 - Installing Firestop steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs and other similar factors may cause poor draft or www.Astria.US.com 126733-01A...
  • Page 16 Vertical Restrictor, Galvanized S-58 Vinyl Siding Standoff, Galvanized WS-58 Wall Strap CS-58 Cathedral Ceiling Support FP-58 Firestop Plate SF-58 Stucco Flashing - For use with Figure 20 - Vertical Venting HTS-58 Configuration Using Two 90° Elbows RF-58 Flat Roof Flashing www.Astria.US.com 126733-01A...
  • Page 17: Fireplace Installation

    (if allowed by local codes) * An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the equipment shutoff valve from your retailer. Figure 21 - External Regulator with Vent Pointing Down (Propane/LP Only) www.Astria.US.com 126733-01A...
  • Page 18 Do NOT Valve Kink PILOT 1/2" NPT Incoming Note: Gas Line 1) Wire connections not Inlet Pressure Tap shown for clarity 2) * 1/8" NPT Plugged Tapping Figure 23 - Connecting Incoming Gas Line to Flex Gas Line www.Astria.US.com 126733-01A...
  • Page 19 2. Open propane/LP supply tank valve for meter for natural gas fireplace or using propane/LP fireplace or main gas valve compressed air. located on or near gas meter for natural gas fireplace. www.Astria.US.com 126733-01A...
  • Page 20 Let cool before removing glass immediately if doors are damaged and doors. contact a qualified installer for repair. Only doors certified with the appliance WARNING: Do not slam or shall be used. strike doors. Damage can result in a hazardous condition. www.Astria.US.com 126733-01A...
  • Page 21 It Figure 28 - Installing Loose Logs is not necessary to use all ember material provided. Loose Log #1 Lava Rock Figure 29 - Installing Lava Rock Figure 28a - Installing Loose Log #1 www.Astria.US.com 126733-01A...
  • Page 22 Valve Control Valve Figure 30 - Installing Ember Flakes To External Regulator (Propane/LP) Flexible Gas Line, Do NOT Kink Figure 32 - Connecting/Disconnecting Gas Line to Millivolt Valve Scrap Log Pieces Figure 31 - Installing Scrap Log Pieces www.Astria.US.com 126733-01A...
  • Page 23 8. Close bottom access door. reinstalling log set/burner module (see replacement parts list on page 32.) Requires 4-AA 1.5V alkaline batteries Learning button Slide Switch REMOTE Frequency adjusting Remote Receiver access hole Figure 34 - Installing Receiver Batteries (Included) www.Astria.US.com 126733-01A...
  • Page 24 Recommended length is ADJ. LEARN no longer than 20 feet The remote control should operate with as little as 9.0 Volts bat- REMOTE tery power. Frequency adjusting Learning access hole button Figure 35 - Adjusting the Receiver www.Astria.US.com 126733-01A...
  • Page 25: Operation

    2. Turn off all electric power to fireplace. 3. Turn safety shutoff switch to the OFF position. 4. Remove center brick/control cover. 5. Turn equipment shutoff valve clockwise to the OFF position (see Figure 36). Do not force. www.Astria.US.com 126733-01A...
  • Page 26: Inspecting Burners

    • Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise Figure 38 - Correct Pilot Flame Pattern to increase the flame to proper size (see Figure 36). Do not remove the adjustment screw. • see Troubleshooting, page 29 www.Astria.US.com 126733-01A...
  • Page 27: Cleaning And Maintenance

    Refer to Removing/Replacing Glass Door, page 20 of this manual when removing door panels with care. Do not glass door for cleaning. strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door unlatched, removed, cracked or broken. www.Astria.US.com 126733-01A...
  • Page 28 WARNING: Do not operate 4. Inspect joints to verify that no pipe section fireplace with glass door un- or fitting has been disturbed and loos- ened. Check mechanical supports such latched, removed, cracked or as wall straps for rigidity. broken. www.Astria.US.com 126733-01A...
  • Page 29: Troubleshooting

    (see Wiring Diagram, page 38). Check for 24 VAC at the second- ary side of transformer. If 24 VAC is present and module does not operate, have module replaced. Other- wise have transformer re- placed www.Astria.US.com 126733-01A...
  • Page 30 If noise is ex- is lit or shut off cooling cessive, contact qualified service person Slight smoke or odor during 1. Residues from manufac- 1. Problem will stop after a few initial operation turing processes and logs hours of operation curing www.Astria.US.com 126733-01A...
  • Page 31 3. Have vent system inspect- sive blockage ed, including termination cap. Remove any restric- tions or obstruction 4. Excessive amounts of em- 4. Clear excess embers until bers and pan material a minimum gap of 1/2" remains under grate www.Astria.US.com 126733-01A...
  • Page 32: Parts

    PARTS MODELS SENTINEL36TEN, SENTINEL36TEP, SENTINEL42TEN AND SENTINEL42TEP 33(36") 32(42") www.Astria.US.com 126733-01A...
  • Page 33 • • • • 123181-01 Log #2 • • 123211-01 Log #3 • • 125104-01 Draft Shield 36" • • 125104-02 Draft Shield 42" • • 109720-03 Spacer Clearance • • • • **Not a field replaceable part. www.Astria.US.com 126733-01A...
  • Page 34 PARTS BURNER ASSEMBLY MODELS SENTINEL36TEN, SENTINEL36TEP, SENTINEL42TEN AND SENTINEL42TEP www.Astria.US.com 126733-01A...
  • Page 35: Burner Assembly

    112799-01 Ember Flakes Kit • • • • 26839 Rockwool • • • • GA6060 Lave Rock Kit • • • • VTA-LS5-2 Log Scrap Kit • • • • 14253 30" Flex Line • • • • www.Astria.US.com 126733-01A...
  • Page 36 PARTS REFRACTORY PARTS Herringbone Brick Shown www.Astria.US.com 126733-01A...
  • Page 37 125095-01 Center Front Refractory 36" White 125095-02 Center Front Refractory 36" Red • • 125130-01 Right Front Refractory 42" White 125130-02 Right Front Refractory 42" Red • • 125094-01 Right Front Refractory 36" White 125094-02 Right Front Refractory 36" Red • • www.Astria.US.com 126733-01A...
  • Page 38: Specifications

    SPECIFICATIONS SENTINEL36TEN SENTINEL36TEP • Rating: 33,500 Btu/hr • Rating: 31,000 Btu/hr • Gas Type: Natural Gas Only • Gas Type: Propane/LP Gas Only • Ignition: Electronic • Ignition: Electronic • Manifold Pressure: 3.5" w.c. • Manifold Pressure: 10" w.c. • Minimum Inlet Supply Pressure: 5" w.c.
  • Page 39: Replacement Parts

    Dual Blower Kit VPBS36 - Ivory LPDBK PBS42 - Red Remote Control Kit - WRC Series VPBS42 - Ivory Standard ON/OFF electronic remote control Magnetic attachment, Matching refractory kit. brick facing surround kit. Ledgestone Refractory Liner Kit BLY36STL BLY42STL www.Astria.US.com 126733-01A...
  • Page 40: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 41 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126733-01A...
  • Page 42 NOTES...
  • Page 43 NOTES www.Astria.US.com 126733-01A...
  • Page 44 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126733-01 1-800-655-2008 Rev. A www.IHP.US.com 1/14 P126733-01...

This manual is also suitable for:

Sentinel36tepSentinel42tenSentinel42tep

Table of Contents