Typical Output Voltage Waveform - Machine Loaded - Lincoln Electric WIRE-MATIC 255 SVM 119-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-23

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

This is a typical DC output voltage wave-
form generated from a properly operating
machine. Note that each vertical division
represents 20 volts and that each horizontal
division represents 5 milliseconds in time.
The machine was loaded with a resistance
grid bank.
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.
TROUBLESHOOTING & REPAIR
MACHINE LOADED TO 250 AMPS AT 26 VDC
WIRE-MATIC 255
SCOPE SETTINGS
Volts/Div . . . . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep . . . . . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . . . .DC.
Trigger . . . . . . . . . . . . . . . . . . .Internal.
F-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wire-matic 255

Table of Contents