Most appliance motors require more than their rated wattage for
startup.
Make sure the electrical rating of the tool or appliance does not
exceed the maximum power rating of the generator.
Maximum power in parallel operation is:
6.0 kVA
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
5.2 kVA
In either case, the total power requirements (VA) of all appliances
connected must be considered. Appliance and power tool
manufacturers usually list rating information near the model number or
serial number.
Substantial overloading that continuously lights the overload
indicator (red) may damage the generator. Marginal overloading that
temporarily lights the overload indicator (red) may shorten the service
life of the generator.