Mitsubishi Electric MS-C18TV-E1 WH Service Manual page 42

Split-type air conditioners
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1)
(2) Disconnect the connector and remove the lead wire from
the fan motor.
(3) Remove the propeller fan nut and remove the propeller fan.
(4) Remove the screws fixing the fan motor.
(5) Remove the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor.
(4) Disconnect lead wires from the glass terminal of the com-
pressor.
(5) Recover gas from the refrigerant circuit.
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(7) Remove the nuts fixing the compressor.
(8) Remove the compressor.
NOTE
Before using a burner, reclaim gas from the pipes until the
pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
2
(MPa).
Photo 4
Propeller fan
Photo 5
Glass
terminal
Discharge
pipe
Compressor
42
PHOTOS
Lead clamp
Hook
Connector
Propeller fan nut
Compressor set nuts
Suction
pipe