Specifications
Function
DC Voltage
(V DC)
AC Voltage
(V AC)
(True rms)
DC Current
(A DC)
AC Current
(A AC)
(True rms)
Resistance
Temperature
NOTE: Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 18
Resolution
Range
200mV
0.1mV
2V
0.001V
200V
0.1V
1000V
1V
2V
0.001V
200V
0.1V
750V
1V
200A
0.1A
200mA
0.1mA
20A
0.01A
200mA
0.1mA
20A
0.01A
200
0.1
2000
1
20k
0.01k
200k
0.1k
20M
0.01M
-20 to
1ºF
750ºC
-4 to 1382ºF 1ºC
o
o
C to 28
C (65
(0.3% reading + 2 digits)
(0.5% reading + 2 digits)
(0.8% reading + 2 digits)
50 to 400Hz
(1.0% reading +6
digits
(1.5% reading +6
digits
(2.0% reading +6
digits
(1.5% reading + 3 digits)
(2.5% reading + 3 digits)
50 to 400Hz
(1.8% reading +8 digits
(3.0% reading +8
digits)
(0.8% reading +4 digits)
(0.8% reading +2 digits)
(1.0% reading +2 digits)
(2.0% reading +5 digits)
(3.0% reading +3 digits)
(meter only, probe accuracy not included)
o
o
F to 83
F) and less than 75% RH.
11
Accuracy
400Hz to 1kHz
(2.0% reading + 8 digits
(2.5% reading +8 digits
(3.0% reading +8 digits
400Hz to 1kHz
(2.5% reading +10
digits)
(3.5% reading +10
digits)
EX411-en-GB_v4.3 4/15