SAfETY pRECAUTIoNS
dANGER!
Electric shock caused by high voltage in the inverter.
Even when no external voltage is present, there can still be high voltages in the device.
The following work may be carried out by qualified personnel only:
• Electrical installation
• Repairs
• Modification
CAUTIoN!
Risk of injury from touching the enclosure during operation.
Burns to the body.
• Only touch the lid and display during operation.
NoTICE!
Overvoltage in the inverter if yellow LED flashes 4 times.
destruction of the inverter.
• Inform your installer immediately if the yellow LED starts
flashing and the following display message appears.
LEd ModES
State
description
All LEDs are
Initialization
on
All LEDs are
Deactivation
off
Green LED
Feeding
is glowing
Operation
continuously
Green LED
Waiting, Grid
is flashing
Monitoring
Stop
Derating
Red LED is
Error
glowing
Yellow LED
Disturbance
is glowing
continuously
Yellow LED
Disturbance
is flashing
MEASURING ChANNELS
If your inverter is equipped with a communication component, then numerous measuring channels
and messages can be transmitted for diagnosis.
Measuring channel
description
Balancer
Displays the currently active operating mode of the inverter which is set
under the operating parameter "PowerBalancer".
Error
Identification of the current disturbance / error.
E-total
Total amount of feeding-in energy
Event-Cnt
Number of events that have occurred
Fac
Grid frequency
h-On
Total number of operating hours
h-total
Total number of grid-feeding operational hours
Iac
Grid current
Ipv
DC current
Mode
Display of the current operating mode
Pac
Generated AC power
Power On
Total number of grid connections
Riso
Insulation resistance of the PV system to the power supply line
Serial number
Inverter serial number
Vac
Grid voltage
Vpv
PV input voltage
Vpv-Setpoint
PV target voltage
function
The inverter is initializing.
The inverter has detected a DC input voltage that is
too low for grid feeding.
The inverter is feeding power into the public grid.
The inverter monitors the grid and waits for the DC
voltage to reach a certain level so that it can start
feeding the grid.
Interruption of operation.
Power limitation in the inverter.
A grounding error has occurred, or one of the
thermally monitored varistors on the DC input side is
defective. Please inform your installer.
The inverter is operating in "Operation constantly
disabled" mode. This can have several causes.
Please inform your installer.
The inverter displays a disturbance. This can have
several causes. Please inform your installer.
pRodUCT oVERVIEw
Identification of the Sunny Mini Central by the type label
Air grills
Enclosure lid
Display
LEDs
Operation
Ground fault or varistor defective
Fault
dISpLAY
operation
The display shows current values of your system. The displayed values
are updated every 5 seconds. The display is operated by tapping on it.
Tap once
The background illumination is switched on. After 2 minutes, the
illumination switches off automatically.
Tap again
The display switches to the next message.
display messages
In operation
Upon error-free connection of the inverter to the grid, the following
messages are shown in turn after approximately 1 minute. Each
message appears for 5 seconds, then the cycle starts again.
Power produced on the current day
Operating state
Current feed-in power
Voltage of the PV generator
Power produced so far
Total number of grid-feeding operational hours
disturbance
In the event of a disturbance, the inverter will display the status
"Disturbance" and an error message. Please inform your installer.
The following messages will be issued:
Power produced on the current day
Operating state "Disturbance"
Operating state
Error message
Measured value at time of disturbance
Current measured value (only displayed if a measured value is
responsible for the disturbance)
dC overvoltage
The DC input voltage connected to the inverter is too high.
Please inform your installer immediately.

STATUS MESSAGES

Your inverter can be in various operating modes. These are displayed as status messages, which can
vary according to the method of communication.
Message
description
Balanced
The inverter has disconnected itself from the grid, or is limiting its output to
5 kVA over a 10 minute average. The inverter is part of a three-phase system
with two further inverters and equipped with the Power Balancer for preventing
unbalanced loads.
Derating
Overtemperature in the inverter. The inverter will reduce its output to prevent
overheating. To avoid unnecessary output losses, the design of the PV plant
should be checked. Please inform your installer.
Disturbance
Disturbance. This message appears for safety reasons and prevents the inverter
from connecting to the grid. Please inform your installer.
Error
An error has been detected. Please inform your installer.
grid mon.
Grid monitoring
This display appears during the start phase, before the inverter is connected to
the grid, predominantly in the mornings and evenings when the solar irradiation
is low and after an error.
MPP
The inverter is operating in MPP mode. MPP is the standard display message
when operating under normal irradiation conditions.
Off Grid
The inverter is in "Island" mode. This mode is specially designed for operation in
island system.
offset
Offset adjustment of measurement electronics.
Riso
Measurement of the insulation resistance of the PV system.
Stop
Interruption of operation.
V-Const
Constant voltage operation.
waiting
The switch-on conditions are not (yet) fulfilled.
Serial number

Advertisement

loading

This manual is also suitable for:

Sunny mini central 8000tlSunny mini central 7000tl