Lincoln Electric SVM188-A Service Manual page 38

Lincoln electric welder user manual
Table of Contents

Advertisement

E-4
CONTROL
POWER
TRANSFORMER
SWITCH
115VAC
Pilot
Light
w
CR2
Secondary
Thermostat
Primary
Theromstat
1CR Coil
CONTACTOR
CR1
PROTECTIVE DEVICES AND
SHUTDOWN CIRCUITS
THERMAL PROTECTION
This welder has thermostatic protection from excessive
duty cycles, overloads, loss of cooling, and high ambi-
ent temperatures. When the welder is subjected to an
overload or loss of cooling, a thermostat will open. The
input contactor will open and remain open until the
machine cools; the white POWER light stays illuminat-
ed. No welding is possible during this cool down peri-
od. The machine will reset automatically when the ther-
mostat cools.
OVER CURRENT PROTECTION
The power source is also protected against overcur-
rents in the SCR bridge assembly through an electron-
ic protection circuit. This circuit senses currents over
780 amps on the power source and opens the input
contactor should the overcurrent remain for a predeter-
mined time (the white POWER light stays illuminated).
The predetermined time varies with the amount of
overcurrent; the greater the overcurrent, the shorter
the time. The input contactor will remain open until the
power source is manually started by resetting the
POWER ON/OFF toggle switch
THEORY OF OPERATION
FIGURE E.2 - GENERAL DISCRIPTION
FAULT PROTECTION
32VAC
32VAC
32VAC
14-pin
115VAC
Amphenol
Receptacle
T
115VAC
S
E
T
R
R
M
I
I
P
N
A
2
L
42VAC
115VAC
MAIN
TRANSFORMER
R
E
C
O
N
N
E
C
T
.
NOTE: Unshaded areas of Block Logic
Diagram are the subject of discussion
DC-600
OUTPUT
CONTROL
SIGNAL
FIRING
BOARD
S
G
I
A
Fan
G
T
Motor
N
E
A
L
CONTROL
OUTPUT
TERMINAL
SWITCH
SHUNT
LATCHING
RESISTOR
SCR BRIDGE
CHOKE
REMOTE CONTROL FAULT PROTECTION
The power source circuitry is protected from faults on
the control circuit leads (#75, 76, or 77). If any of these
leads become common with either of the output leads,
the DC-600 will either shut down completely (control
lead fault to Negative Output), or will remain at mini-
mum output (control lead fault to Positive Output) thus
preventing any damage to the DC-600. If DC-600 shuts
down, (input contactor opens and white POWER light
stays illuminated) it must be manually started by reset-
ting the POWER ON/OFF toggle switch.
TERMINAL
STRIP 1
OUTPUT
CONTROL
SWITCH
OUTPUT
CONTROL
BOARD
MODE
SWITCH
F
E
E
D
B
A
C
POSITIVE
K
TERMINAL
F
E
E
D
B
A
C
NEGATIVE
TERMINAL
K
E-4