Santon SPEEDIBOIL SP2.5 Installation And User Instructions Manual

Santon SPEEDIBOIL SP2.5 Installation And User Instructions Manual

Hide thumbs Also See for SPEEDIBOIL SP2.5:

Advertisement

SPEEDIBOIL
Installation and User Instructions
Models: SP2.5, SP5.0, SP7.5
Please read and understand these instructions before starting work.
Please leave this leaflet with the user following installation.
WARNING
This boiling Water Heater must only be installed
by qualified persons.
36006034 Issue 4
1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPEEDIBOIL SP2.5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Santon SPEEDIBOIL SP2.5

  • Page 1 SPEEDIBOIL Installation and User Instructions Models: SP2.5, SP5.0, SP7.5 Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation. WARNING This boiling Water Heater must only be installed by qualified persons. 36006034 Issue 4...
  • Page 2 INTRODUCTION Thank you for purchasing a Santon Speediboil . The boiling water heater is manufactured to the highest standards and has been designed to meet all the latest relevant safety specifications. This Speediboil water heater must be installed (Sections 1-5), commissioned (Section 6) and maintained (Sections 7-8) by a competent person.
  • Page 3: Component Checklist

    COMPONENT CHECKLIST Before commencing installation check that all the following components have been supplied with your Speediboil • Wall mounting bracket • No.12 x 2" screws (2 off) • No.8 x 1" screw (1 off) • No.12 x 2" wall plug (2 off) •...
  • Page 4: Important Installation Points

    1.0 IMPORTANT INSTALLATION POINTS The Speediboil stores and dispenses water at or close to boiling point at all times it is switched on. Due caution must be taken when choosing a location for the product to minimise misuse. Locate the unit over a draining board, NOT over the sink or basin.
  • Page 5: Installation - Mounting

    2.0 INSTALLATION - MOUNTING The Speediboil must be vertically wall mounted using the bracket supplied. Fig.1, page 6 details the outside dimensions of the Speediboil. It is recommended that the unit is positioned above the draining board. If this is not possible, consideration should be given to any spillages that may occur under the appliance.
  • Page 6 Fixing Bracket Fixing Hole Worktop Figure 1 MODEL DIMENSIONS (mm) INLET VENT INLET/ CABLE INLET/ VENT ENTRY VENT SP2.5 SP5.0 SP7.5...
  • Page 7: Installation - Water Supply

    CABLE FIXING FIXING BRACKET BRACKET BRACKET OUTLET ENTRY POINT POINT SP2.5 52.5 SP5.0 SP7.5 3.0 INSTALLATION - WATER SUPPLY Select appropriate push fit connector for chosen entry position: Bottom entry water - 15mm x 15mm 90º elbow. Rear entry water - 15mm x 15mm straight. NOTE: Stainless or chromed pipes DO NOT provide secure connections with push fit fittings (use copper pipe at joints).
  • Page 8: Installation - Electrical Requirements

    5.0 INSTALLATION - ELECTRICAL REQUIREMENTS WARNING: This appliance must be earthed. The installation, supply cable and circuit protection must conform to the latest BS7671 ‘Requirements for electrical installations’ (IEE Wiring Regulations). The appliance must only be connected to a 230/240 V ac supply. A double pole isolating switch, with a contact separation of at least 3mm in both poles, must be incorporated in the electrical supply.
  • Page 9 6.0 COMMISSIONING The electronic control system of the Speediboil has a self commissioning and calibration function. Once the heater is installed and all services have been connected, the appliance should require no further adjustment before use. Check that all electrical, water and vent pipe connections have been made and are secure.
  • Page 10: Maintenance

    7.0 MAINTENANCE NOTE: Maintenance must be carried out by competent persons. Competent - i.e. Trained, experienced, qualified. Disconnect the electrical supply before removing the cover. WARNING: Electronics control by switching ‘N’ (neutral), in some instances neutral terminations will be at 230 volts with respect to earth. The Speediboil incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas.
  • Page 11: Fault Finding

    Flashing – unit commissioning On steadily – normal operation continue to use Off – unit too cold For any faults that cannot be identified using the Fault Finding chart please contact Santon After Sales Service, telephone (0844) 871 1530, fax (0844) 871 1528.
  • Page 12: Spare Parts

    9.0 SPARE PARTS The following comprehensive list of spare parts is available for your Santon Speediboil water heater. Please refer to the rating label on the right hand side of your heater before ordering to ensure the correct spare parts are obtained.
  • Page 14 10.0 USER INSTRUCTIONS 10.1 Once installed, the filling and the heating cycles of the Speediboil are completely automatic. 10.2 To dispense water, place a suitable container under the outlet spout and pull the tap handle down and towards (or push away from) the user. The water dispensed will at all times be boiling or close to boiling point so due caution must be taken when using the product.
  • Page 15: Environmental Information

    This guarantee in no way affects the statutory rights of the consumer. The policy of Santon is one of continuous product development and, as such, we reserve the right to change specifications without notice. Environmental Information Santon products are manufactured from many recyclable materials.
  • Page 16: Spares Stockists

    Unit D5 Enterprise Way Vale Park, Evesham Worcestershire WR11 1GS or contact your local supplying merchant or wholesale branch Hurricane Way, After Sales Tel: (0844) 871 1530 Norwich, After Sales Fax: (0844) 871 1528 Norfolk, NR6 6EA. ServiceEmail: santonservice@ www.santon.co.uk heateam.co.uk © 2013...

This manual is also suitable for:

Speediboil sp7.5Speediboil sp5.0

Table of Contents