Kenwood NX-200 K2 Service Manual page 55

Vhf digital transceiver
Table of Contents

Advertisement

Item
Panel tuning mode
5. Open
1) Adj item: [An SQL]
Squelch
Adjust: [✳✳✳]
adjust *6
2) Adj item:
(Squelch
[AnL SQL]→
level 5
[AnL' SQL]→
adjust)
[AnC SQL]→
[AnH' SQL]→
[Analog
[AnH SQL]
Narrow]
Adjust: [✳✳✳]
SSG output: 12dB
SINAD level
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw SQL]
Wide]
Adjust: [✳✳✳]
2) Adj item:
[AwL SQL]→
[AwL' SQL]→
[AwC SQL]→
[AwH' SQL]→
[AwH SQL]
Adjust: [✳✳✳]
SSG output: 12dB
SINAD level
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [Nv SQL]
Very
Adjust: [✳✳✳]
Narrow]
2) Adj item:
[NvL SQL]→
[NvL' SQL]→
[NvC SQL]→
[NvH' SQL]→
[NvH SQL]
Adjust: [✳✳✳]
SSG output: 12dB
SINAD level for Ana-
log Narrow –4dB
(MOD: 400Hz/±1.1kHz)
*6: Because Open Squelch (NXDN Narrow) is adjusted by adjusting Open Squelch (Analog Narrow), it is not necessary to adjust Open Squelch
(NXDN Narrow).
6. Low RSSI
1) Adj item: [An LRSSI]
at –118dBm
Adjust: [✳✳✳]
adjust *7
2) Adj item:
[AnL LRSSI]→
[Analog
[AnL' LRSSI]→
Narrow]
[AnC LRSSI]→
[AnH' LRSSI]→
[AnH LRSSI]
Adjust: [✳✳✳]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item:
SSG
[Open Squelch
Distortion
(Analog Narrow)]
meter
2) Adj item: [Low],
Oscilloscope
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level
(MOD: 1kHz/±1.5kHz)
1) Adj item:
[Open Squelch
(Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level
(MOD: 1kHz/±3kHz)
1) Adj item: [Open
Squelch (NXDN
Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level for Ana-
log Narrow –4dB
(MOD: 400Hz/±1.1kHz)
1) Adj item: [Low RSSI
SSG
(Analog Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Universal
connector
Panel
ANT
Universal
connector
NX-200
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
"Open Squelch"
After input signal
will not be adjusted
from SSG, press
correctly if MOD
[ ] key to store the
and Deviation are
adjustment value.
wrong.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the ana-
log signal.
This item is ad-
justed under the
condition that MOD
is "400Hz" and De-
viation is "±1.1kHz"
due to the circuit
confi guration.
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks
55