Kenwood NX-200 K2 Service Manual page 51

Vhf digital transceiver
Table of Contents

Advertisement

Item
Panel tuning mode
10. Single
1) Adj item: [An TONE]
Tone
Adjust: [✳✳✳✳]
Deviation
Deviation meter
adjust *4
LPF: 15kHz
HPF: OFF
[Narrow]
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw TONE]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
11. MSK
1) Adj item: [An MSK]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw MSK]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
12. CWID
1) Adj item: [Nv CWID]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 15kHz
[Very
HPF: OFF
Narrow]
PTT: ON
Press [ ] key to store
the adjustment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on pages 52 and 53.
13. VOX1
1) Adj item: [VOX1]
adjust
Adjust: [✳✳✳]
AG: 1kHz/45mV at
MIC terminal
14. VOX10
1) Adj item: [VOX10]
adjust
Adjust: [✳✳✳]
AG: 1kHz/3mV at
MIC terminal
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Single
Deviation
Tone Deviation
meter
(Analog Narrow)]
Oscilloscope
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [MSK Devia-
tion (Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [MSK Devi-
ation (Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [VOX1]
AG
AG: 1kHz/45mV at
MIC terminal
1) Adj item: [VOX10]
AG: 1kHz/3mV at
MIC terminal
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
Universal
connector
NX-200
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
1.50kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
[
],
value)
[
]
[PC test
mode]
[ ],[ ]
3.00kHz±0.05kHz
Write the value as
1.50kHz±0.05kHz
followings.
513 (Reference
value)
3.00kHz±0.05kHz
Write the value as
1.10kHz±0.10kHz
followings.
376 (Reference
value)
[Panel tuning mode]
After apply signal
from AG, press [ ]
key to store the
adjustment value.
[PC test mode]
After apply signal
from AG, press
[Apply] button to
store the adjust-
ment value.
Remarks
51