Installation; Technical Specifications - Lincoln Electric RANGER 275 Operator's Manual

Lincoln electric welder user manual
Hide thumbs Also See for RANGER 275:
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS - Ranger 275 Kohler Engine (K1641-1)
Make/Model
Description
Kohler
2 cylinder
20.0 HP @
CH20
3600 RPM
Full Load
Gas Engine
Welding Output
CC Stick/TIG, Pipe and CV Wire Welding
275 Amps
300 Amps
HEIGHT
30.3 in.
770 mm
1. Duty cycle is based on a 10 minute period. This machine can be loaded to 300 amps for 6 minutes out of every 10 minute
period.
2. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.

INSTALLATION

INPUT - ENGINE
Speed (RPM)
High Idle 3700
Low Idle 2400
Full Load 3400
RATED OUTPUT - WELDER
Volts at Rated Amps
28 volts
25 volts
OUTPUT - GENERATOR
Auxiliary Power
9,000 Watts, 60 Hz
120/240 Volts
100 % Duty Cycle
115/42 Volt Auxiliary Power for Wire Feeders
PHYSICAL DIMENSIONS
WIDTH
19.1 in.
485 mm
RANGER 275
Displacement
Starting
System
38 cu. in(624 cc)
12VDC battery
(Group 58, 435
cold crank amps)
Bore x Stroke
3.03" x 2.64"
25 A. Alternator
(77 mm x 67 mm)
Duty Cycle
1
100%
60%
2
DEPTH
42.0 in.
1067 mm
A-1
Capacities
Fuel: 9.0 gal.
(34 L)
Oil: 2.0 Qts.
(1.9 L)
Max. OCV @ 3700 RPM
80 volts DC
WEIGHT
469 lbs.
212 kg.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents