Lincoln Electric RANGER 275 Operator's Manual page 30

Lincoln electric welder user manual
Hide thumbs Also See for RANGER 275:
Table of Contents

Advertisement

C-4
ACCESSORIES - CONNECTION DIAGRAMS
RANGER 275 / LN-25 WITH K624-1 42 VOLT REMOTE OUTPUT
14 PIN
AMPHENOL
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. PLACE THE MODE SWITCH IN THE "WIRE WELDING-CV" POSITION. PLACE WELDER TERMINALS SWITCH TO "REMOTELY
CONTROLLED" POSITION.
N.B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER VOLTMETER SWITCH TO
MATCH THE POLARITY OF THE ELECTRODE CABLE.
N.C. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPLICATIONS. SEE OPERATING MANUAL.
N.D. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.
N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.
14 PIN
AMPHENOL
6 PIN
TO WORK
AMPHENOL
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPLICATIONS. SEE OPERATING MANUAL.
N.B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER VOLTMETER SWITCH
TO MATCH POLARITY OF THE ELECTRODE CABLE.
N.C. PLACE THE MODE SWITCH IN THE " WIRE WELDING-CV" POSITION.
N.D. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.
N.E. PLACE IDLER SWITCH IN "HIGH" POSITION.
CONTROL MODULE CONNECTION DIAGRAM
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
TO WORK
ELECTRODE
TO WORK
RANGER 275 / LN-7 CONNECTION DIAGRAM
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
ELECTRODE
TO WORK
RANGER 275
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
TO LN-25 INPUT
CABLE PLUG
K626-XX INPUT CABLE ASSEMBLY
ELECTRODE CABLE
TO WIRE FEED UNIT
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
TO LN-7 INPUT
CABLE PLUG
K584 CONTROL CABLE
ELECTRODE CABLE
TO WIRE FEED UNIT
C-4
A
S24095-3
OPTIONAL K857
REMOTE CONTROL
A
S24095-4