Chamberlain LiftMaster PROFESSIONAL SL580 Manual
Chamberlain LiftMaster PROFESSIONAL SL580 Manual

Chamberlain LiftMaster PROFESSIONAL SL580 Manual

Table of Contents

Advertisement

Quick Links

GL
MODEL SL580
H
D
S
G
O
EAVY
UTY
LIDE
ATE
PERATOR
MODEL SL590
H
D
, H
E
EAVY
UTY
ARSH
NVIRONMENT
S
G
O
LIDE
ATE
PERATOR
2 YEAR WARRANTY
Serial # ________________________
(located on electrical box cover)
Installation Date __________________
MODELS SL580 AND SL590 ARE FOR VEHICULAR PASSAGE GATES ONLY
AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LiftMaster PROFESSIONAL SL580 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chamberlain LiftMaster PROFESSIONAL SL580

  • Page 1 MODEL SL580 EAVY LIDE PERATOR MODEL SL590 EAVY ARSH NVIRONMENT LIDE PERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) Installation Date __________________ MODELS SL580 AND SL590 ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S OPERATOR SPECIFICATIONS IMPORTANT NOTE Carton Inventory ........2 •...
  • Page 3: Gate Speed & Horsepower Chart

    G A T E S P E E D A N D H O R S E P O W E R C H A R T Model H.P. Gate Speed Max. Gate Weight Max. Cant’l. Width Max. O/H Width Max.
  • Page 4: Model Classifications

    U L 3 2 5 M O D E L C L A S S I F I C A T I O N S CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith.
  • Page 5: Installation

    U L 3 2 5 M O D E L C L A S S I F I C A T I O N S c o n t i n u e d SAFETY ACCESSORY SELECTION UL325 ENTRAPMENT PROTECTION REQUIREMENTS All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized GATE OPERATOR ENTRAPMENT PROTECTION...
  • Page 6: Gate Systems

    G A T E S Y S T E M S COMMERCIAL SLIDE GATE Telephone Open Entry Edge System Photo Eye For Close Open Cycle Edge Run Twisted Wire From Loop Street To Operator* Seal Loops* Interrupt Loop 1-1/2" Typical Loop Wire* Photo Eye For Typical...
  • Page 7: Safety Installation Information

    S A F E T Y I N S T A L L A T I O N I N F O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 8: Safety Label Placement

    S A F E T Y L A B E L P L A C E M E N T The UL required Warning Signs must be installed in plain view and on both sides of each gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner.
  • Page 9: Safety Precautions For Open Roller Gates

    S A F E T Y P R E C A U T I O N S F O R O P E N R O L L E R G A T E S Injuries occur when people get their hands or feet caught between the top or bottom of the gate and the gate roller. This potential pinch-point should be guarded against at all times.
  • Page 10: Pad Mounting (Sl580)

    P A D M O U N T I N G ( S L 5 8 0 O N L Y ) CONCRETE PAD PREPARATION Figure 1 Conduit End Post Entry Area NOTE: For the following instructions refer to Figures 1 and 2. 3/4"...
  • Page 11: Post Mounting (Sl580)

    P O S T M O U N T I N G ( S L 5 8 0 ) POST PREPARATION (SL580 ONLY) Figure 1 End Post Fence Line NOTE: For the following instructions refer to Figures 1 and 2. Gate 1.
  • Page 12: Post Mounting (Sl590)

    P O S T M O U N T I N G ( S L 5 9 0 ) POST PREPARATION (SL590 ONLY) Figure 1 End Post Fence Line NOTE: For the following instructions refer to Figures 1 and 2. Gate 8-3/4"...
  • Page 13: Gate Bracket & Drive Chain Installation

    G A T E B R A C K E T & D R I V E C H A I N I N S T A L L A T I O N Figure 1 WARNING WARNING "Outside" When pulling the chain through the operator, the limit shaft will turn.
  • Page 14: Manual Disconnect (Sl580)

    M A N U A L D I S C O N N E C T NOTE: When the operator is under load, you may find it necessary to relieve the tension on the drive chain before disengaging the system. MODEL SL580 (Refer to Figure 1) Figure 1 DISENGAGEMENT:...
  • Page 15: Caution Warning

    I N S T A L L P O W E R W I R I N G & C O N T R O L S T A T I O N WARNING WARNING WARNING ANY maintenance to the operator or in the area near the operator DISCONNECT power at the fuse box BEFORE proceeding.
  • Page 16: Disconnect Switch Power Wiring

    D I S C O N N E C T S W I T C H P O W E R W I R I N G NOTE: Before running power wiring refer to wiring specifications Important: On three phase operators, power connections must be on page 15 for correct wire gauges.
  • Page 17: Programming The Radio Receiver

    P R O G R A M M I N G T H E R A D I O R E C E I V E R WARNING WARNING SET SECURITY MODE CAUTION WARNING The Universal Receiver can be used with up to 15 rolling code transmitters or passwords in HIGH security mode.
  • Page 18: Limit Switch Adjustment For Gate Travel

    L I M I T S W I T C H A D J U S T M E N T F O R G A T E T R A V E L MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE WARNING WARNING LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH...
  • Page 19: Sams

    S A M S ( S E Q U E N C E D M A N A G E M E N T S Y S T E M ) SAMS DEFINITION The Sequenced Access Management System or SAMS allows the customer more control when managing vehicular entrances to areas such as apartment complexes, businesses and gated communities.
  • Page 20: Optional Control Devices

    O P T I O N A L C O N T R O L D E V I C E S All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon UL325, and include recommendations for significant increase in safety.
  • Page 21 O P T I O N A L C O N T R O L D E V I C E S c o n t ’ d Terminals 9 & 5 - Obstruction Open (Edge/ Photo Eye Input) OBSTRUCTION OPEN (EDGE/PHOTO EYE INPUT) Edge Input: See Programming Section 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 This input will reverse an opening gate to the close limit.
  • Page 22: Control Board Illustration

    C O N T R O L B O A R D I L L U S T R A T I O N S J4 Connector Master/Second J1 Connector Dip Switch #4 Main Terminal Master/Second Wiring Potentiometer Timer to Close Potentiometer Force Adjustment Dip Switch #2...
  • Page 23: Controller Programming And Features

    C O N T R O L L E R P R O G R A M M I N G A N D F E A T U R E S MOTOR LEARN FUNCTION (FORCE PROFILE) MOTOR LEARN BUTTON This function is preprogrammed at factory.
  • Page 24: Program Settings

    P R O G R A M M I N G S E T T I N G S ( D I P S W I T C H # 1 ) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode must be set to the OFF position. TIMER TO CLOSE ENABLE TIMER TO CLOSE This switch (S1-1) enables the auto close timer.
  • Page 25 P R O G R A M M I N G S E T T I N G S ( D I P S W I T C H # 2 ) c o n t i n u e d EDGE/PHOTO OPEN EDGE/PHOTO CLOSE This switch (S2-3) selects edge or photo sensor for the gate...
  • Page 26: Friction Type Slipping Clutch

    F R I C T I O N T Y P E S L I P P I N G C L U T C H WARNING WARNING WARNING To avoid SERIOUS PERSONAL INJURY or DEATH This friction clutch system is NOT an automatic reversing DISCONNECT electric power BEFORE adjusting clutch.
  • Page 27: Troubleshooting

    T R O U B L E S H O O T I N G ➤ " SYMPTOMS POSSIBLE CAUSES SOLUTIONS Operator fails to run " No stop control ➤ Check the green LED (D17) on GL board. If the green LED is off, check to make sure a stop control has been installed across terminals J1-3 and J1-5 of the GL board.
  • Page 28 T R O U B L E S H O O T I N G c o n t ’ d Operator runs in wrong direction " Operator’s main power is out of phase (three phases only) ➤ Turn off the unit’s main power at the breaker and swap any two power leads at the operator’s main power switch. Apply power and retest the operator. See important note on page 16.
  • Page 29: Hall Effect Sensor Adjustment

    H A L L E F F E C T S E N S O R A D J U S T M E N T NOTE: Normally the Hall Effect sensor does not need adjustment, WARNING but may go out of alignment due to shipping vibration or rough handling.
  • Page 30: Operator Maintenance

    O P E R A T O R M A I N T E N A N C E CHECK AT LEAST ONCE EVERY DESCRIPTION TASK 3 MONTHS 6 MONTHS 12 MONTHS " Internal speed sensor Check for proper operation External entrapment "...
  • Page 31: Individual Parts

    R E P A I R P A R T S - S L 5 8 0 Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Please consult a parts and service representative regarding availability of individual components.
  • Page 32: Illustrated Parts (Sl580)

    I L L U S T R A T E D P A R T S - S L 5 8 0...
  • Page 33: Repair Parts (Sl590)

    R E P A I R P A R T S - S L 5 9 0 Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Please consult a parts and service representative regarding availability of individual components.
  • Page 34: Illustrated Parts (Sl590)

    I L L U S T R A T E D P A R T S - S L 5 9 0...
  • Page 35: Variable Parts (Sl580)

    V A R I A B L E P A R T S S L 5 8 0 & S L 5 9 0 Variable Description Used On 20-1050C-2T 1PH 1/2HP C-FACE 115/230 TEFC SL580-50-11, SL580-50-21 20-1075C-2T 1PH 3/4HP C-FACE 115/230V TEFC SL580-75-11, SL580-75-21 20-1100C-2T 1PH 1HP C-FACE 115/230V TEFC...
  • Page 36: Warranty Policy / Repair Parts And Service

    HOURS 8:00 a.m. TO 6:00 p.m. (Central Std. Time) SATURDAY WWW.LIFTMASTER.COM WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Electronic Parts & Service Dept. 6020 S. Country Club Road Tucson, AZ 85706...
  • Page 37: Single Phase Wiring Diagram (Sl580)

    S I N G L E P H A S E W I R I N G D I A G R A M ( S L 5 8 0 ) GL CONTROL BOARD GL CONTROL BOARD PRIMARY J2 PLUG 3.15A (GY) 2 4 VAC- IN...
  • Page 38: Three Phase Wiring Diagram (Sl580)

    T H R E E P H A S E W I R I N G D I A G R A M ( S L 5 8 0 ) GL CONTROL BOARD 3.15A ALARM ASSY 24VAC 24VAC 76-G0537 24V Sec. 24VAC 24VAC COMMON...
  • Page 39: Single Phase Wiring Diagram (Sl590)

    S I N G L E P H A S E W I R I N G D I A G R A M ( S L 5 9 0 ) 230 ONLY SEE NOTE 5 GL CONTROL BOARD GL CONTROL BOARD 115 ONLY SEE NOTE 1 SEE NOTE 5...
  • Page 40: Three Phase Wiring Diagram (Sl590)

    T H R E E P H A S E W I R I N G D I A G R A M ( S L 5 9 0 ) 3.15A ALARM ASSY GL CONTROL BOARD 76- G0 5 37 24V SEC.
  • Page 41: Operator Notes

    O P E R A T O R N O T E S...
  • Page 42 O P E R A T O R N O T E S...
  • Page 43 O P E R A T O R N O T E S...
  • Page 44: Control Connection Diagrams

    If these instructions are contrary to the advice given here, call for assistance. VISIT US AT WWW.LIFTMASTER.COM 01-18473F © 2004, The Chamberlain Group, Inc. All Rights Reserved...

This manual is also suitable for:

Liftmaster professional sl590

Table of Contents