Technical Data Table - Ferroli PEGASUS F2 N T Instructions For Use, Installation And Maintenance

Cast iron gas boiler for central heating
Table of Contents

Advertisement

Pegasus F2 N T

4.3 Technical data table

MODEL
Powers
Heating Power (Net Heat Value - Hi)
Useful heating power
Gas supply
Pilot nozzle G20-G25
Pilot nozzle G31
Main nozzles G20
Feed pressure G20
Pressure at burner G20
Delivery G20
Main nozzles G25
Supply pressure G25
Pressure at burner G25
Delivery G25
Main nozzles G31
Supply pressure G31
Pressure at burner G31
Delivery G31
Heating
Maximum working temperature
Maximum working pressure in heating
N° elements
Minimum working pressure in heating
N° burner trains
Boiler water content
Dimensions, weights connections
Height
Width
Depth
Weight with packing
Gas system connection
Heating system delivery
Heating system return
Electrical power supply
Max electrical power absorbed
Power voltage/frequency
Electrical protection rating
51
kW
56
kW
51
mm
1 x 0.40
1 x 0.40
mm
1 x 0.24
1 x 0.24
mm
3 x 3.50
4 x 3.50
mbar
20.0
mbar
13.3
nm 3 /h
5.9
mm
3 x 3.50
4 x 3.50
mbar
25.0
mbar
13.3
nm 3 /h
5.9
mm
3 x 2.15
4 x 2.15
mbar
37.0
mbar
36
kg/h
4.34
°C
100
bar
6
4
bar
0.8
3
litres
22
mm
1000
mm
550
mm
900
kg
250
inches
3/4"
inches
1" 1/2
inches.
1" 1/2
W
5
V/Hz
230/50
IP
X0D
68
85
74.8
93.5
68
85
1 x 0.40
1 x 0.24
5 x 3.50
20.0
20.0
13.3
13.3
7.9
9.9
5 x 3.50
25.0
25.0
13.3
13.3
7.9
9.9
5 x 2.15
37.0
37.0
36
36
5.79
7.24
100
100
6
6
5
6
0.8
0.8
4
5
26
30
1000
1000
640
720
900
900
300
350
3/4"
3/4"
1" 1/2
1" 1/2
1" 1/2
1" 1/2
5
5
230/50
230/50
X0D
X0D
102
112.0
102.0
1 x 0.40
1 x 0.24
6 x 3.50
20.0
13.3
11.8
6 x 3.50
25.0
13.3
11.8
6 x 2.15
37.0
36.0
8.68
100
6
7
0.8
6
34
1000
800
900
400
3/4"
1" 1/2
1" 1/2
5
230/50
X0D
25