RX-V861/HTR-6080/DSP-AX861SE/DSP-AX861

Starting DIAG

Note) Before activating the DIAG function, set the
sound field program on the main unit to any
setting item other than "2ch Stereo".
If setting is at "2ch Stereo" when the DIAG
function is activated, "SURROUND BACK L/R"
and "EXTRA SP L/R" may fail to turn on.
Press the "MASTER ON/OFF" (RX-V861 / HTR-6080:
G model) / "STANDBY/ON" (HTR-6080: U, C models /
DSP-AX861SE / DSP-AX861) key while simulta-
neously pressing those two keys of the main unit as
indicated in the figure below.
RX-V861 / HTR-6080 (G model)
HTR-6080 (U, C models) /
DSP-AX861SE / DSP-AX861

Starting DIAG in the protection cancel mode

If the protection function works and causes hindrance
to trouble diagnosis, cancel the protection function as
described below, and it will be possible to enter the
DIAG mode. (The protection functions other than the
excess current detect function will be disabled.)
Press the "MASTER ON/OFF" (RX-V861 / HTR-6080:
G model) / "STANDBY/ON" (HTR-6080: U, C models /
DSP-AX861SE / DSP-AX861) key while simulta-
neously pressing those two keys indicated in the fig-
ure above. At this time, keep pressing those two keys
for 3 seconds or longer.
In this mode, the [SLEEP] segment of the FL display
of the main unit flashes to indicate that the mode is
DIAG mode with the protection functions disabled.
CAUTION!
Using this product with the protection function dis-
abled may cause damage to the main unit. Use spe-
cial care for this point when using this mode.