TEST DESCRIPTION
This test will determine if the Output Rectifier is shorted. See the Oscilloscope
Waveforms section of this manual for normal and abnormal output waveforms.
MATERIALS NEEDED
3/8" Nut Driver
5/16" Nut Driver
1/2" Wrench
Power MIG 350 Wiring Diagram (See the Machine Schematic in this manual.
Analog Volt/Ohmmeter (If Digital Meter is used you must use in Diode Check Mode
TROUBLESHOOTING & REPAIR

OUTPUT RECTIFIER ASSEMBLY TEST

WARNING
Do not use Ohms Scale)