22.02.1996 / Page 4
Doc. No: 4812 718 11648

Technical data

Reedcontact
flow meter
salt control
rinse aid control
Spray arm block
NTC
15 ˚C
20 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
75
kΩ
62
kΩ
43
kΩ
28
kΩ
19
kΩ
13
kΩ
9
kΩ
6
kΩ
5
kΩ
Whirlpool Europe
Customer Service
Regeneration
Volume
Position 0
after wash cycles
water hardness
Position 1
after wash cycles
water hardness
Position 2
after wash cycles
water hardness
Position 3
after wash cycles
water hardness
Position 4
after wash cycles
water hardness
Position 5
after wash cycles
water hardness
Position 6
after wash cycles
water hardness
Salt consumption
for regeneration
Number of cycles
with 2 kg salt
S E R V I C E
300
cm
--
0-5
˚dh
0-0,9
mmol/l
0-9
˚Fh
6-8
6-10
˚dh
1-1,8
mmol/l
10-18
˚Fh
5-6
11-15
˚dh
1,9-2,7 mmol/l
19-27
˚Fh
4
16-21
˚dh
2,8-3,7 mmol/l
28.37 ˚Fh
3
22-28 ˚dh
3,8-5,0 mmol/l
38-50 ˚Fh
2
29-35 ˚dh
5,1-6,3 mmol/l
51-63
˚Fh
1
36-60 ˚dh
6,4-10,7mmol/l
64-107 ˚Fh
77
g
26