Power feed 10 dualwire drives & control boxes boom mount or bench model
Table of Contents

Advertisement

C-7
which procedure the gun switch is requesting.
Memory Selection
RECALL - When a memory key is depressed its indi-
cator comes on, and its contents are copied to the
active procedure. As long as no changes are made to
the contents of that procedure, the memory indicator
will be on anytime that procedure is active. This indi-
cates that their contents are the same. Any change to
that procedure will cause the memory indicator to go
off, indicating that they are no longer equal.
SAVE - The save mode allows "hard" memories to be
changed. Pressing the SAVE key will light the save
indicator, and enter the save mode. In the save mode,
the indicator for the memory that was the source of
the active procedureʼs contents will blink, whether
their contents are still equal or not. This feature allows
the user to choose to save an active procedure back
to its source, or some other location.
To complete the save transaction requires the selec-
tion of one of the memory keys. When the memory
key is pressed in the save mode, itʼs contents are
overwritten with the contents of the active procedure.
This means that the contents of the memory location
and the active procedure are now equal, and there-
fore, by definition, each of their indicators will be lit,
and the save mode will be exited. To exit the save
mode without saving, depress the save key a second
time. This feature allows the operator to determine the
source of the active procedureʼs contents without
actually overwriting it.
Installation is as follows:
1. Turn off power.
2. Remove the two screws from the front of the stan-
dard or option panel at the location you choose to
install your new option, (middle), of the Control
Box cabinet. Save the screws for re-use. Unplug
the white electrical connector. Remove the chas-
sis wire (if equipped) from the back of the stan-
dard or option panel. Discard the old panel or
save for future use.
3. Tilt the new option panel away from the front
opening of the Control Box cabinet and plug the
white electrical connector into the proper connec-
tor on the right side of the main printed circuit
board (10 pin) until the connector latches into
place. Attach the chassis wire (if equipped) to the
back of the new panel.
4. Slide the new panel through the opening, taking
care not to damage the connections and the print-
ed circuit board on the back.
5. Align the screw holes. Replace the two screws
and tighten.
ACCESSORIES
K1543, K1544 AND K1545 INPUT
CABLE ASSEMBLIES
Available Cable Assemblies:
K1543 - Control cable only. Consists of a 5-conductor
control cable with a 5-pin control cable plug, without
electrode cable, and is available in lengths of 8', 16',
25', 50' and 100'.
K1544 - Consists of a 5-conductor control cable with a
5-pin control cable plug and a 4/0 electrode cable. It is
rated at 600 amps, 60% duty cycle and is available in
lengths of 8', 16', 25', and 50'.
K1545 - Control cable and a 4/0 (85 mm2) electrode
cable with Twist-Mate™ connector on one end and a
stud terminal on the other. It is rated at 500 amps,
60% duty cycle and is available in lengths of 8', 16',
25', and 50'.
With input power disconnected from the power
source, install the Control Cable Assemblies per the
instruction in INSTALLATION - "Cable Connections".