Electrical Adjustments
Group/
Item Name
Item
3 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
17 Temp C Warning Offset
(Temp)
18 Temp B-A Warning Offset
(Temp)
19 Temp C-A Warning Offset
(Temp)
20 Temp A Warning Offset
(Time)
Temp B Warning Offset
21
(Time)
22 Temp C Warning Offset
(Time)
23 Temp B-A Warning Offset
(Time)
Temp C-A Warning Offset
24
(Time)
25 Factory Mode
Group
Fan control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
3 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min
9 High Fan4 Max
10 Normal Fan Control Min
Temp
Normal Fan Control Max
11
Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Normal Fan4 Min
19 Normal Fan4 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
Function
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco (Panel)
Temp. C to judge the Temp Error at
Eco (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
For factor use
Temp Senser Control Start/End Temp.
at High
Fan voltage value at High (unit: 0.1V)
Temp Senser Control Start/End Tem.
p at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.
p at Eco
Fan voltage value at Eco (unit: 0.1V)
Initial
100
100
100
100
100
100
100
100
46
46
46
46
60
61
56
54
65
65
63
63
100
100
100
100
100
100
100
100
46
46
45
45
60
61
55
54
65
64
62
62
100
100
100
100
100
100
100
100
5
5
15
0
0
5
5
18
1
1
0
Normal Ceiling HiLand-
HiLand-
Normal
Ceiling
38
38
34
33
43
43
40
38
85
85
105
105
135
135
135
135
85
85
110
110
130
130
130
130
75
75
100
100
77
77
115
115
9999
9999
9999
9999
38
39
35
33
43
43
40
38
70
70
95
95
125
125
125
125
75
75
100
100
120
120
120
120
85
85
105
105
85
85
110
110
9999
9999
9999
9999
38
39
35
32
42
43
39
38
60
60
95
95
115
115
115
115
68
68
90
90
110
110
110
110
-44-
range Note
0-100
0-100
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-1
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
-
-
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
-
-
20-100
20-100
0-255
0-255
0-255
0-255

Advertisement

Table of Contents
loading

Table of Contents