SPECIFICATIONS
Natural Gas BTU Input
Propane Gas BTU Input
Co-axial DV Vent Size
NOTES
All specifications, ratings and dimensions are
subject to change without notice.
Appliance has a factory-installed vent seal cap
(see Figures 16 & 17 on Page 16) in each flue
outlet.
25-5/16 (643)
22 (559)
37-1/16
(941)
18-1/4
(465)
15-3/4 (400)
19-11/16 (500)
Left Side View
Figure 14
14
Fireplace Framing Specifications
30,000
***This dimension does
28,000
not include the addition
of drywall to the inside of
4-1/2" Inner /
framing or clearance for
7-1/2" Outer
the Side Vent Seal Cap.
Adjust accordingly for your
installation.
See also, Side Vent Seal Cap
note below.
37-3/16
(945)
Framing Spacers
(top and both sides)
1-1/4
(44)
37-1/16
(941)
29-3/16
18-1/4
(741)
(464)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Notes:
***38-3/4
(984)
5-5/8
(143)
Top View
Optional
Blower
Vent Seal Cap
41-13/16 (1062)
40-1/4 (1022)
35-1/4 (895)
29 (737)
32-5/8 (829)
Front View
Installation and Operation Instructions
• Inches (millimeters)
• Minimum Framing Stud Size is 2 x 4
• See side views of fireplace below for
gas line inlet location options.
**20-3/4
(527)
Vent Center - Top Vent
10-1/2
with one 90 degree
(267)
elbow
12-1/8
(308)
5-1/8
(130)
Vent Center - Side Vent
with no elbows
12-1/8
(308)
Center of gas line
is 3-1/8 inches
(79 mm) up from
floor.
10-7/8 (264)
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to
11 (279)
locate center of the vertical run. Cut and/or
frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about
this center mark (see Figure 20).
5/8
(16)
4-15/16
(125)
Provide
additional
space for
Side Vent
Seal Cap if
installing
against
a solid
wall.
25-1/2
(648)
3-1/8 (79)
Control Compartment
Door
900300-00, 02/2015
**This dimension
based on 5/8" drywall.
For 1/2" drywall use
21" (533 mm). The
finished dimension
should be 22" (558
mm)
Secure Vent
42-3/4 (1086)
Secure Flex
43-1/2 (1105)
5-1/8
(130)
25-1/2
(648)
11 (279)
Control Switch Wires
Knock-Out
25-1/2
(648)
Gas
Inlet
6-1/4
(159)
Junction Box Knock-Out
(2 places each side)