MINIMUM CLEARANCES
Sides
Top of Appliance
Floor
From Bottom of Unit To Ceiling
Vent
SERVICE CLEARANCES
Front, Back, Sides
Table 5
Combustible Materials
Allowed In Shaded Area
"Safe Zone"
Inches (millimeters)
At 5" minimum side
wall clearance, the wall
(shown in dark gray) can
be any length.
o
45
5
4
3
2
(127)
(102)
(76)
(51)
Figure 9
*
Inches (millimeters)
1/2 in. (13)
0 (0) from Spacers Or Dimples **
5 (127)
0 (0)
72 (1829)
3 (76)
* / 1 (25.4)
Top
Sides & Bottom
Feet (meters)
3 feet (0.9 meters)
Top View of
Fireplace
Minimum
1
(25)
Distance to
2
(51)
Unprotected
3
Side Wall
(76)
4
(102)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(250)
1
One end of the unit may be
flush with a perpendicular
(25)
wall, but the wall at the other
end must not extend beyond
the front edge of the unit.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically
approved with this appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces
ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifiquement
approuvées avec cet appareil sont utilisées.

DETAILED INSTALLATION STEPS

The appliance is shipped with all gas controls and components installed
and pre-wired.
1. Remove the shipping pad, exposing the front face assembly with barrier
and hood. Remove the hood by pulling firmly straight away from the unit.
2. Remove the face assembly with barrier by lifting the front face as-
sembly approximately 1/2" then pull straight out away from the fireplace
until the mounting tabs clear, exposing the glass door.
3. Open the two latches (located under the firebox floor) securing the
glass door. Remove the door by tilting it outward at the bottom and
lifting it up. Set the door aside protecting it from inadvertent damage.
See Removing and Installing Glass Panels on Page 35.
4. Lift the pressure relief plates and remove the cardboard from beneath
each plate (be careful not to damage the white gasket).
Installation and Operation Instructions