Removing the Battery
The battery 3 is equipped with two locking lev-
els that should prevent the battery from falling
out when pushing the battery unlocking button
23 unintentionally. As long as the battery is in-
serted in the power tool, it is held in position by
means of a spring.
To remove the battery 3, press the battery un-
locking button 23 and pull the battery out of the
power tool toward the rear. Do not exert any
force.
Mounting/Replacing the Saw Blade
Before any work on the power tool, remove
the battery.
When mounting the saw blade, wear protec-
tive gloves. Danger of injury when touching
the saw blade.
Only use saw blades that correspond with
the characteristic data given in the operat-
ing instructions.
Do not under any circumstances use grind-
ing discs as the cutting tool.
Selecting a Saw Blade
An overview of recommended saw blades can
be found at the end of this manual.
Removal of the Saw Blade (see figure A)
For changing the cutting tool, it is best to place
the machine on the face side of the motor hous-
ing.
– Press the spindle lock button 14 and keep it
pressed.
The spindle lock button 14 may be actuated
only when the saw spindle is at a standstill.
Otherwise, the power tool can be damaged.
– With the Allen key 16, unscrew the clamping
bolt 21 turning in rotation direction
– Tilt back the retracting blade guard 7 and
hold firmly.
– Remove the clamping flange 20 and the saw
blade 19 from the saw spindle 17.
2 609 932 639 | (11.7.08)
Mounting the Saw Blade (see figure A)
For changing the cutting tool, it is best to place
the machine on the face side of the motor hous-
ing.
– Clean the saw blade 19 and all clamping
parts to be assembled.
– Tilt back the retracting blade guard 7 and
hold firmly.
– Place the saw blade 19 onto the mounting
flange 18. The cutting direction of the teeth
(direction of arrow on the saw blade) and the
direction-of-rotation arrow on the retracting
blade guard 7 must correspond.
– Mount the clamping flange 20 and screw in
the clamping bolt 21 turning in rotation di-
rection
. Observe correct mounting posi-
tion of mounting flange 18 and clamping
flange 20.
– Press the spindle lock button 14 and keep it
pressed.
– Tighten the clamping bolt 16 with the Allen
key 21 by turning in rotation direction
tightening torque is 6–9 Nm, which corre-
sponds to hand tight plus ¼ turn or
3 graduation marks of the marks 22 on the
blade guard 4.

Dust/Chip Extraction

Before any work on the power tool, remove
the battery.
Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one's health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
.
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
– To achieve a high degree of dust extrac-
tion, use the vacuum cleaner type GAS
25/GAS 50/GAS 50 M for wood or GAS
50 MS for wood and/or mineral dust in
conjunction with this power tool.
. The