LEFT DISPLAY SELECTION
The left display can show either amperage or actual
WFS during welding. Note that actual WFS is not the
same as preset WFS. For example, the preset WFS
may be set to 400 ipm, but the arc voltage is only 15V.
The actual WFS will be approximately 280 ipm
because there is not enough arc voltage to run at 400
ipm.
To change the left display reading:
Rotate the WFS knob to the left to display amperage
(current).
Rotate the WFS knob to the right to display actual
WFS.
Then rotate the knob to the 12 oʼclock position.
c
d
I
SP
u r r
A
V
O O
O O WFS
Press the set-up button.
WFS KNOB RANGE
For wire feeders equipped with standard torque gear-
ing, the WFS range can be changed to provide better
knob sensitivity at low wire feed speeds. This is often
useful when welding with Innershield™ wires.
To change the WFS knob range:
Rotate the WFS knob to the left for the low wire feed
speed range of 40 – 405 ipm
Rotate the WFS knob to the right for the high wire
feed speed range of 40 – 715 ipm.
Then rotate the knob to the 12 oʼclock position.
P d
S
I o
A
V
O O
O O WFS
Press the set-up button.
OPERATION
I SP
F
E
E
d
d
A
V
O O
O O WFS
H I
S
P d
A
V
O O
O O WFS
LN-25™ PRO DUAL POWER
= Calibration Factor Example:
B-8