Dell PowerVault MD3200i Hardware Installation And Troubleshooting Manual page 48

Storage arrays with microsoft windows server failover clusters
Hide thumbs Also See for PowerVault MD3200i:
Table of Contents

Advertisement

Setting up In-Band Management (Optional)
Out-of-band management is the recommended method for managing the
storage array. However, to optionally set up in-band management, configure
the following:
Controller 0: IP: 192.168.128.101 Subnet Mask: 255.255.255.0
Controller 1: IP: 192.168.128.102 Subnet Mask: 255.255.255.0
NOTE:
The management station you are using must be configured for network
communication to the same IP subnet as the PowerVault MD3200i or MD3220i iSCSI
host ports.
1 Establish an iSCSI session to the MD3200i or MD3220i RAID storage
array.
2 Restart the SMagent service.
3 Launch MD Storage Manager, and then click New.
NOTE:
Storage Array window appears.
4 Select Manual and click OK.
5 Select In-band management and enter the host server name(s) or
IP address(es) of the attached host that is running the MD Storage
Manager software.
6 Click Add.
In-band management is now successfully configured.
Configuring Host Access
If the host context agent is running on the host, the hosts and the host ports
connected to the storage array are automatically detected by MDSM and
appear on the Mappings tab in the Array Management window.
If the host is not detected:
1 Launch MDSM.
2 Navigate to the Array Management window and click Manually Define
Hosts.
3 In the Enter Host Name field, enter the host server for virtual disk
mapping. This can be an informal name, not necessarily a name used to
identify the host server to the network.
48
Preparing Your Systems for Clustering
When you set up the first storage array management, the Add New

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3220i

Table of Contents