RANGER 9 / K867 / LN-8 CONNECTION DIAGRAM
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
14 PIN
AMPHENOL
ELECTRODE
TO WORK
ELECTRODE CABLE
TO WIRE FEED UNIT
TO WORK
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION. PLACE WELDING TERMINALS SWITCH TO
"REMOTELY CONTROLLED " POSITION.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. SPLICE LEADS AND INSULATE.
N.E. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.
RANGER 9 / LN-742 CONNECTION DIAGRAM
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
14 PIN
AMPHENOL
TO WORK
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPLICATIONS. SEE OPERATING MANUAL.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.
N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.
WARNING
SPARE
K867 UNIVERSAL
GND
ADAPTER PLUG
WARNING
TO LN-742 INPUT
CABLE PLUG
K592 CONTROL CABLE
ELECTRODE
TO WORK
– 33 –
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
82
81
N.C.
42
41
31
31
32
32
2
2
4
4
21
21
GND
75
A
76
B
77
C
N.D.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
ELECTRODE CABLE
TO WIRE FEED UNIT
LN-8
WIRE
FEEDER
K196
INPUT CABLE
1 2 - 1 6 - 9 3
M 1 7 0 9 4
1 2 - 1 6 - 9 3
M 1 7 1 0 0