FIGURE A.1 - POWER-ARC 4000 OUTPUT CONNECTIONS
1. CURRENT CONTROL DIAL
2. WELD OUTPUT TERMINALS (2)
3. GROUND STUD
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.1 for the location of the current control
dial, weld output terminals, ground stud, circuit
breakers, 240 and 120 volt receptacles.

WELDING CABLE CONNECTIONS

Cable Size and Length

Be sure to use welding cables that are large enough.
The correct size and length becomes especially
important when you are welding at a distance from
the welder.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
INSTALLATION
80
70
AMPS
AMPS
125
90
AMPS
AMPS
GENERATOR
100
AMPS
WARNING
ELECTRODE SELECTION GUIDE
2
POWER-ARC 4000
1
POWER ARC 4000
3
4
4. CIRCUIT BREAKERS (2) - 20 AMP
5. RECEPTACLE - 240 VOLT, 20 AMP
6. DUPLEX RECEPTACLE - 120 VOLT, 20
AMP
RECOMMENDED WELDING CABLE
SIZE AND LENGTH
TOTAL COMBINED LENGTH OF ELECTRODE AND
WORK CABLES
Cable Length
0-50 feet (0-15 meters)
50-100 feet (15-39 meters)
100-150 feet (30-46 meters)
150-200 feet (46061 meters)
200-250 feet (61-76 meters)
6
5
TABLE A.1
Cable Size for
125 amp/
30% Duty Cycle
6 AWG
4 AWG
3 AWG
2 AWG
1 AWG