Specification Of Electrical Parts; Indoor Unit (Ras-13Ukhp-E4, Ras-10Ukhp-E4, Ras-07Ukhp-E4); Outdoor Unit (Ras-13Uah-E4) - Toshiba RAS-13UKHP-E4 Service Manual

Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-13UKHP-E4, RAS-10UKHP-E4, RAS-07UKHP-E4)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Module (M01)
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
13
Relay (Comp., RY01)
14
Relay (Fan, RY03)
15
Relay (Solenoide, RY04)

4-2. Outdoor Unit (RAS-13UAH-E4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
SKF-220-20-4A-1
µRM1260V
TMP87CM40AN
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
BET 6.3A
15G561K
RF-2TK5R6
MP24Z
DI1U
G5NB-1A
G5NB-1A
Type
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH225X2C-4FT
Winding resistance ( )
(at 20 C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
HF-240-42A
Winding resistance ( )
(at 20 C)
DS451155BPQC
AC 450 V, 1.5mF
DS371356CPNB
AC 370 V, 35mF
- 18 -
Specifications
AC Motor with 150 C thermo fuse
°
W
10k at 25 C
DC 390V, Secondary DC 12V
°
W
10k at 25 C
27mH, 600mA
4A, 600 V
47mF, 400 V
T6.3A, 250VAC
560 V
W
5.6
, 2 W
12VDC
Rating 25A/AC250 V, 3-48VDC
Rating 3A/AC250 V, 12VDC
Rating 3A/AC250 V, 12VDC
Specifications
W
°
W
°
FILE NO. SVM-05001
°
C-R
C-S
2.35
3.22
Red-Black
White-Black
176.2
290.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents