4-9. Outdoor Unit (RAS-07UAX4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay

4-10. Outdoor Unit (RAS-07UA-E4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
Type
Output (Rated) 605W, 2poles, 1 phase, 220 − 240V, 50Hz
Winding resistance (Ω)
PH108X1C-4DZDN2
(at 20°C)
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-20B or
Winding resistance (Ω)
SKF-240-20B
(at 20°C)
DS451155BPQC
AC 450V, 1.5µF
DS371256CPNB
AC 370V, 25µF
JMRA99208-9201
U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
Type
Output (Rated) 605W, 2poles, 1 phase, 220 − 240V, 50Hz
PH108X1C-4DZDN2 Winding resistance (Ω)
(at 20°C)
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-20B or
Winding resistance (Ω)
SKF-240-20B
(at 20°C)
DS451155BPQC AC 450V, 1.5µF
AC 370V, 25µF
DS371256CPNB
JMRA99208-9201 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
− 22 −
FILE NO. SVM-05001
Specifications
C-R
4.84
Red-Black
387.3 or 235.2 466.2 or 260.1
Specifications
C-R
4.84
Red-Black
White-Black
387.3 or 235.2 466.2 or 260.1
C-S
4.40
White-Black
C-S