5-5. RAS-10UKP-E4 / RAS-10UA-E4
RAS-10UKPX4 / RAS-10UAX4
Cooling
0.39 m
(Connecting pipe)
Æ9.52
O.D.:9.52 mm
P
Packed valve
(Æ9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
RM5510GNE94
Heat exchanger
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.54
0.65
0.48
− 27 −
FILE NO. SVM-05001
T1
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 1100l
Refrigerant
R22 : 0.68 kg.
Mark (
) means check points of Gas Leak.
Fan speed
(indoor)
13.0
High
17.0
High
5.0
Low
0.49 m
(Connecting pipe)
Æ6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15