Kenwood KRF-V5090D Service Manual page 8

Audio-video surround receiver
Hide thumbs Also See for KRF-V5090D:
Table of Contents

Advertisement

F
G
Q Q
3 7 6 3 1 5 1 5 0
(X08-3420-10)
R693
100
R694
R792
100
18K
C792
470P
D603
1
XTO
2
XTI
33
R IN
R641
3
32
D VDD
L IN
4.7
31
1/4W
R OUT1
31
4
30
D VSS
IC602
L OUT1
30
29
R OUT2
29
5
CODEC
28
T VDD
L OUT2
28
(ADC&DAC)
6
27
TX
R OUT3
27
R689 22
7
26
MCKO
L OUT3
26
R679 22
25
8
C621
LRCK
DZF1
24
2.2u50
R678 22
9
V COM
+
BICK
23
R642 22
VREF H
+5V
10
SDTO
R796 22
11
SDTI 1
R797
22
R798
22
44
+5V
+5V
T E
14
L
1 3 9 4 2 2 9 6 5 1 3
12
10
8
IC605
LEVEL
SHIFTER
1
IC606
LEVEL
SHIFTER
13
11
9
+5V
+2.5V
+2.5V
+3.3V
+3.3V
+5V
+5V
R921
CN901
2.2
1
VID. G GND
C908
C907
100P
X09-A/9-
C915
R907
100P
2
CTLB
WH120
w w w
470u16
75
R911 4.7K
Q902
3
V.MUTE
+
2/4
C917
R912 220
R917
+11.5V
4
CTLA
10K
100P
C913
5
+12V
P-5
47u25
6
+
.
Q901
D902
D901
D900
H
I
+5V
IC607
DAC
R652
C765
22
1
16
2200P
44
MCLK
DZFL
15
R653
DZFR
C761
R779
R765
22
2
10u50
2.2K
2.2K
43
BICK
R791
R654
14
+
VDD
22
3
18K
SDTI
C791
R655
13
470P
22
4
VSS
C681
42
LRCK
22P
D602
5
PDN
R656
12
22
C682
6
VCOM
19
CSN
22P
11
AOUTL
C762
R780
R766
10u50
2.2K
2.2K
R657
10
R640
AOUTR
220
7
+
4.7
18
CCLK
C766
R658
1/4W
2200P
220
8
9
17
CDTI
PS
C703
FILTER
2200P
FL
IC701 (1/2)
C701
R701
R705
R741
10u50
2.2K
2.2K
3
30
1
220
+
2
8
C700
47P
+12V
IC701
(2/2)
R742
6
C702
R702
R706
220
7
10u50
2.2K
2.2K
5
31
+
4
C704
12V
2200P
FR
C713
820P
SL
IC702 (1/2)
C711
R711
R715
R743
10u50
3.3K
2.2K
3
28
1
220
+
2
8
+12V
IC702
(2/2)
R744
6
C712
R712
R716
7
220
10u50
3.3K
2.2K
5
29
+
4
12V
C714
820P
SR
C723
2200P
CENTER
IC703 (1/2)
C721
R721
R725
R745
10u50
2.2K
2.2K
3
26
1
1K
+
2
8
C719
47P
+12V
IC703
(2/2)
R746
6
C722
R722
R726
100
7
10u50
15K
18K
5
27
+
4
12V
C724
8200P
SW
D604
+2.5V
IC609
1
5
VSS
CE
2
C656
R812
R664
Q606
V IN
47u25
1
3
4
560
V OUT
EXT
+
1/4W
1/4W
+2.5V AVR
C654
R666
10u50
18 2W
+9.9V
+
D606
IC611
C661
0.01
4
3
C
CTL
2
R670
GND
D607
5
1
4.7
+3.3V
OUT
VCC
1/4W
C665
Q609
33P
+3.3V AVR
x
a o
+5V
IC612
y
AVR
5.1V
+5V
OUT VCC
+B
GND
i
J
K
8
+5V
SBL
C773
SBL
10u50
Q607
+
C735
+12V
100P
R771
C781
8
R646
C731 10P
3
220
4.7u50
1
1K
2
+
R759 10K
IC708
(1/2)
R760 10K
C732 10P
R772
C782
6
7
220
4.7u50
C736
C774
5
+
10u50
100P
4
IC708
+
(2/2)
SBR
5.1V
SBR
+12V
+12V
12V
12V
CONFIGURATION
IC705
R753
1
30
4.7K
VSS
VDD
2
29
FL
FR
R751
3
28
SL
SR
4.7K
4
27
SL IN2
SR IN2
5
26
6
25
7
24
8
23
9
22
10
21
11
20
12
19
SW
13
18
C744
N.C.
N.C.
100P
14
17
ST
DATA
17
15
16
Q
GND
Q
CK
16
3
7
6
3
14
+12V
IC707
R748
IC707
SW
R747
100
(2/2)
(1/2)
100
MIX
CN605
19
18
CP605
180
17
17
R756 180
16
16
14
CP603
14
15
180
11
14
8
13
9
12
1
11
R757 180
19
10
CP604
9
180
10
8
44
7
20
6
13
5
4
R758 180
12
3
R685
+9.9V
+8.8V
2
1
1
1/4W
A
C624
C633
220P
100P
CHANNEL
SPACE
C632
SW
220P
R674
4.7K
S601
R673
100kHz
50kHz
D608
u 1 6 3
47K
D609
CN603
X09-G/9-
CN606
WH110
+9.9V
1
AC
.
0V
1
2/4
2
Q608
2
AC
3
AD-4
KRF-V5090D/V6090D (1/4)
VR-905/906 (1/4)
11
L
M
KRF-V5090D/V6090D/VR-905/906
2
4
9
9
8
CN604
IC704
1
(1/2)
C733
R777
2
3
8
22u50
2.2K
1
R781
2
J604
+
100
L
R775
SURR BACK
1K
PRE OUT
R
Q701
R776
R782
1K
100
Q702
CN601
IC704
R922
25
PROT
(2/2)
0
C734
R778
6
24
M GND
22u50
2.2K
7
5
+12V
23
+12V
+
4
22
A GND
12V
21
-12V
20
SBL-IN
19
SBR-IN
18
FR
17
SR IN2
16
A GND
X09-B/9-
15
SW
CN201
14
A GND
3/4
AN-1
13
SBL-OUT
12
SBR-OUT
11
CENTER
10
SL IN2
9
FL
8
A GND
7
RREC
6
A GND
5
LREC
4
A GND
2.5V
33
3
R IN
2
A GND
2.5V
32
1
L IN
CAUTION: For continued safety, replace safety critical com-
ponents only with manufacturer's recommended parts (refer
to parts list).
continued protection against risk of fire, replace only with
1
5
1
5
0
8
9
2
4
same type and rating fuse(s). To reduce the risk of electric
shock, leakage-current or resistance measurements shall be
carried out (exposed parts are acceptably insulated from the
supply circuit) before the appliance is returned to the cus-
tomer.
(X08-3420-10)
DESTINATION
MODEL NAME
UNIT No.
A
B
COUNTRY
ABB.
VR-905
CANADA
P5
0-10
NO
NO
The DC voltage is an actual reading measured with a high
U.S.A.
K6
VR-905-S
0-10
NO
NO
CANADA
P6
impedance type voltmeter with no signal input. The mea-
U.S.A.
K7
VR-906
0-10
NO
NO
surement value may vary depending on the measuring
P7
CANADA
U.S.A.
K8
instruments used or on the product.
0-10
NO
NO
VR-906-S
CANADA
P8
PX
Y1
2-92
YES
NO
KRF-V5090D
CODEC INT
EUROPE
E1
0-10
NO
NO
DSP IRQ 1
PX
Y2
2-92
YES
NO
KRF-V5090D-S
AUSTRALIA
X2
0-10
NO
NO
EUROPE
E2
SEL DATA
PX
Y3
2-91
YES
YES
SEL CLK
KRF-V6090D
EUROPE
E3
0-11
NO
YES
ST1
AUSTRALIA
X4
KRF-V6090D-S
0-11
NO
YES
EUROPE
E4
DSP CLK
DSP D OUT
X14-A/2-
CN803
DSP D IN
DIGITAL LINE
DSP CE1
SIGNAL LINE
4/4
AU-5
GND LINE
CODEC CSN
+B
B LINE
CODEC PD
B
B LINE
CODEC DVF
DSP PD
S DATA
IC601
:
CS493263-CLZ
D601,608,613,614
S BUSY
IC602
:
AK4586VQP
:
1SS355
IC603
:
TC7WU04FU-F
D602,605
:
1SS301 or
50/75uS
IC604
:
TC7WH123FU-F
DAN202U
DIG DET
IC605
:
TC74HCT7007AF
D603
:
1SS300 or
+8.8V
IC606
:
TC74HC07AF
DAP202U
M GND
IC607
:
AK4384
D604
:
UDZS3.9B or
IC609
:
XC62EP2502MRN
HZU3.9(B2)
IC611
:
BA033LBSG2
D606,607
:
UDZS5.6B or
IC612
:
BA05T
HZU5.6(B2)
IC701-704,707,708
D609
:
D2SBA207009F01
:
NJM4565MD-ZB
D610,612
:
UDZS5.1B or
IC705
:
NJU7311AM-ZB
HZU5.1(B2)
m
IC901,902
:
MM1228XFBE-E
D611
:
UDZS6.2B or
HZU6.2(B2)
Q601,901,902
D900-902
:
1SR154-400
:
DTC124EUA
c o
Q606
:
2SB1375
Q607,608
:
2SC4081(R,S)
Q609
:
2SA1576A(R,S)
Q701,702
:
2SC4213(B)
S BUSY
S DATA
GND
N
O
2
9
9
indicates safety critical components. For
9
8
2
9
9
12
X08-3420-10(2/2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents