Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a
current exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated output of the gen-
erator.
Style
NOTE :
When the no-fuse breaker turns off during operation, the generator is over loaded or the appli-
ance is defective. Stop the generator immediately, check the appliance and / or generator for
overloading or detect and have repaired as necessary by Robin dealer or service shop.
CAUTION
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter).
GFCI shuts off the output current from the duplex 120V receptacle when a ground fault
occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
Ampere
Receptacle
NEMA
up to 20A
5-20R
NEMA
up to 30A
L5-30R
NEMA
up to 30A
L14-30R
up to 50A
NEMA
up to 30A
L21-30R
AC plug
NEMA
5-20P
NEMA
L5-30P
NEMA
L14-30P
Locking Receptacle
(REC4)
NEMA
L21-30P
TABLE 1
12
Description
GFCI (Ground Fault Circuit
Interrupter) Receptacle, duplex
(REC1)
Locking Receptacle
(REC2)
Locking Receptacle
(REC3)
Locking Receptacle
(REC5)