The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats are set to a specific tempera-
ture such as 72°. The control of this heater
establishes a "comfort level". In order for the
thermostat to operate effectively, the heater
should be the main source of heat in the room.
Follow the instructions for lighting the heater
on page 18. When the room reaches the
desired comfort level, rotate the control knob
clockwise
slowly to the point where
the main burner extinguishes (this point on
the dial will change depending on the room
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. Remove screen by lifting and pulling
forward.
2. Follow steps 1 through 5 under Lighting
Instructions, page 18.
3. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
200176-01A
OPERATION
THERMOSTAT CONTROL OPERATION

TO TURN OFF GAS TO APPLIANCE

to the

MANUAL LIGHTING PROCEDURE

www.sureheat.com
temperature), then back counterclockwise
, just until the flame reignites. Leave the
knob in this position. As the room temperature
increases, the burner will "turn to LOW" setting
or extinguish. When the room temperature
cools, the heater will come back on. If left
at this set point, the thermostat will turn the
main burner off and on as needed to maintain
the temperature at this comfort level setting.
Note: The thermostat sensing bulb measures
the temperature depending on housing con-
struction.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
PILOT position.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Make sure the heater screen is in place
before operating heater.
to the