Cleaning or servicing the inlet valve may be required if the unit has priming problems. Priming problems may be
prevented by properly cleaning the sprayer and following the long-term storage steps.
1. Remove the suction set.
If you have a model XT290 or XT330, loosen the fitting
as shown (a) and remove the Sureflo™ valve solenoid.
If you have a model XT250, skip to step 2.
(a)
3. Replace inlet valve assembly by screwing it into the
sprayer.
XT250
English
Cleaning the Inlet Valve
2. Unscrew the inlet valve assembly (b) from the sprayer.
Visually inspect the inside and outside of the inlet valve
assembly. Clean any paint residue with the appropriate
cleaning solution.
XT250
4. Replace Sureflo™ valve solenoid.
If priming problems persist, you may need to replace the
inlet valve assembly. Call Technical Service to order new
inlet valve assembly.
20
(b)