Page 1
Outlet Box, Canopy, Slide Grip Hanger
Assemble Slide Grip Hanger to Fixture as in
7
Step 2. Bring service leads from Outlet Box
through AC1 and Slide Grip Hanger, securing AC1
and Slide Grip Hanger to Outlet Box.
Outlet
Box
AC1
K.O.'s (2)
Slide Grip
Hanger
End
Plate
Surface Mount Direct to Surface Without Slide
8
Grip Hanger
Insert Flexible Connector with at least 1/2" long
leads into wiring compartment and secure the
Wiring
Compartment
Flexible Connector with the Flexible Connector
Locknut. Mount the Fixture to the ceiling with
Mounting Screws (by others) or toggle bolts (not
supplied) through four 7/32" x 9/32" rectangular
holes. Make sure Fixture is mounted firmly and
the ceiling can withstand the weight of the Fixture.
Make electrical connections to Fixture, using twist-
on wirenuts provided. Re-install Wireway Cover,
install lamps (by others). Slip Ball Chain into key
slots in Wireway Cover and Install Louver.
Fixture
Flexible
Connector
Flexible
Connector Locknut
Mounting
Screw
Lightolier
45 INDUSTRIAL WAY, WILMINGTON, MA 01887
LYTECEL LINEAR SURFACE/PENDANT AND ELECTRICAL FEED INSTRUCTIONS
NOTE: Fixture should be installed by a qualified electrician. Before installation, see dimensions.
Dimensions
1
Remove Wireway Cover
to expose Wirenuts
Wago Plug-in
Twist-on
Wirenuts
for thru wiring
Wirenuts
4'
Unit
Continuous End
Feed End
Remove Wireway Cover
Twist-on
tp expose Wirenuts
Wirenuts
for thru wiring
8'
Unit
Feed End
2
Slide Grip Hanger Assembly
and make wiring connections. If Fixture is to be
End Or Middle of Row
used as an individual, or mounting is to be at
joints, assemble Slide Grip Hanger to both ends of
Remove Louver by releasing four Spring-loaded
Latches. Remove Wireway Cover. Remove K.O.s
1st Fixture.
(2) from top of End Plate and install Slide Grip
Assemble End Cap to Fixture with Screws (2)
Hanger into K.O. openings. Secure Slide Grip
Provided at end of row. Install Wireway Cover and
Hanger to Fixture with Screw Provided. Feed
Louver.
wires through opening in End Plate, into Wireway
Slide
Screw
Grip
K.O.s
Hanger
Provided
Tab
Wago
Plug-ins
Fixture
End Cap
Wireway
Cover
Ball
Chain
Louver
Screw
Provided
© a Genlyte company
59-31135-000
Wago Plug-in
Wirenuts
Continuous End
Screw
Provided
Slide
Grip
Hanger
Fixture
Printed in U.S.A.

Advertisement

loading

Summary of Contents for Lightolier Lytecel Linear Surface/Pendant And Electrical Feed

  • Page 1 Wireway Cover and Install Louver. Screw Lightolier 45 INDUSTRIAL WAY, WILMINGTON, MA 01887 LYTECEL LINEAR SURFACE/PENDANT AND ELECTRICAL FEED INSTRUCTIONS NOTE: Fixture should be installed by a qualified electrician. Before installation, see dimensions. Dimensions Remove Wireway Cover to expose Wirenuts...
  • Page 2 Lytecel 6-page Inst. Sht.qxd 2/25/05 4:40 PM Page 2 Stem Set for End of Row or Continuous Row Mounting with Reflector or without Reflector. Slip threaded end of stem through Canopy. Attach Stem(s) to Slide Grip Hanger using Nuts as shown. Assemble Slide Grip Hanger to Fixture Slide Rails.

This manual is also suitable for:

Lytecel linear surface/pendant