2 Specifications and Controls
2.4 Heat Pump Curves
16
14
12
10
8
6
4
2
0
-10
Figure 2-5: Grant HPAW65
16
14
12
10
8
6
4
2
0
-10
Figure 2-6: Grant HPAW85
16
14
12
10
8
6
4
2
0
-10
Figure 2-7: Grant HPAW110
4
Water Flow
Temperature
35˚C
50˚C
0
10
20
30
Air Temperature in ˚C
Water Flow
Temperature
35˚C
50˚C
0
10
20
30
Air Temperature in ˚C
Water Flow
Temperature
35˚C
50˚C
0
10
20
30
Air Temperature in ˚C
16
14
12
10
8
COP
6
4.1
4
2
0
40
-10
Figure 2-8: Grant HPAW130
16
14
12
10
COP
8
3.9
6
4
2
0
40
-10
Figure 2-9: Grant HPAW155
!
NOTE
All Grant Aerona heat pumps have
COP
4.3
been independently third party
tested to BS EN 14511. The COP
data given above is based on 7˚C
ambient air and 35˚C water
temperature. This information should
be used as guidance only and not to
estimate the COP at other
40
temperatures.
Water Flow
Temperature
35˚C
50˚C
0
10
20
30
Air Temperature in ˚C
35˚C
Water Flow
Temperature
50˚C
0
10
20
30
Air Temperature in ˚C
COP
4.8
40
COP
5.8
40