2 Specifications and Controls

2.1 Specifications

Model
Heating Capacity
Max. Running Current at 240V*
Power supply
Phase
Frequency
Mechanical Protection
Refrigerant
Mass of R407c
Built In Immersion
Circulating Pump
Flow Rate
Sound Level at 1m
Water Connections
COP @ Air 7˚C/Water 35˚C
Weight (empty)
Weight (full)
* Includes 3kW immersion heater.

2.2 Dimensions

90
Figure 2-1: HPAW65 model
90
2
Figure 2-2: HPAW85, HPAW110 & HPAW130 models
HPAW65
kW
6.78
A
23
V
220/240
Single
Hz
50
IP X4
R407c
g
1300
kW
3
m head
6
litres/sec
0.311
dB(A)
53
BSPF
3
/
4
4.1
kg
100
kg
116
1120
Front View
900
90
1120
Front View
900
90
HPAW85
HPAW110
8.73
11.32
27
220/240
220/240
Single
Single
50
IP X4
IP X4
R407c
R407c
1750
1900
3
6
0.422
56
"
3
/
"
4
3.9
121
139
430
165
50
50
Flow
Return
Rear View
400
70
200
430
50
50
110
Flow
Return
Rear View
400
265
HPAW130
12.58
28
30
220/240
Single
50
50
IP X4
R407c
2200
3
3
6
6
0.54
0.61
56
59
1"
1"
4.3
4.8
141
144
159
162
Electrical inlet
glands
Electrical inlet
glands
HPAW155
15.5
36
220/240
Single
50
IP X4
R407c
2300
3
15
0.724
63
1"
5.8
172
191

Hide quick links: