July 2011
REV B
How to Program the Temperature
Offset
Note: This procedure will only need to be performed
if the temperature display is being replaced or if the
saved data is corrupted and needs to be reset.
Note: Genie programs a default value of +30° F / -
1.1° C for temperature offset.
1 See How to Program the Temperature Display
and access the
OFSET
2 To enter the offset value, press the
blank (unmarked) button to increment the
flashing digit or the sign of the number. To select
a new digit or sign of the number, press the
button.
Note: If no digits are flashing, press the blank button
to toggle the sign of the number or press the
button to wrap around to the LSD.
3 After the desired offset value is on the display,
press and hold the
SEL
enter the value and return to the main menu.
4 Remove the jumper wire from the back of the
temperature display.
Result: The display will show
programming changes are being saved into
memory.
Note: Do not turn the machine off before removing
the jumper from the back of the display. If the
machine is turned off before the jumper wire is
removed, all data may not save completely or
correctly. This could result in a fault display of
the next time the machine is turned on.
Part No. 107713