Download Print this page

Lighting Systems - Lightolier Lighting Systems RT6-5 Specification Sheet

Lighting systems lytetube indirect lens 2-light t8 per 4-foot section

Advertisement

Performance and Quick Calculator
CANDLEPOWER CURVE
180˚ 175˚
165˚
155˚
145˚
135˚
1200
1000
125˚
800
115˚
600
105˚
400
200
95˚
0
90˚
85˚
200
400
75˚
600
65˚
800
1000
55˚
1200
0˚ 5˚
15˚
25˚
35˚
45˚
REPORT NO: LRL 489-10E
LAMPS: 2-32WT8
LUMENS: 2900
EFFICIENCY: 62.0%
Fixture Lengths & Mounting Locations
4-FOOT JOINER
48" (121.92cm)
Sample Run
96" (243.84cm)
POWER FEED
SINGLE
END SET
STEM OR CABLE
8-FOOT JOINER
20' 6" (624.84cm)
Mounting & Joiner Block Accessories
3" (7.62cm)
6" (15.24cm)
9" (22.86cm)
3"
3"
Power Feed End Set
Power Feed End Set
Chrome Stem
Cable/Cord
RT62 ED12 = 12" OAL
RT62 EDCC36
RT62 ED18 = 18" OAL
(straight cord)
RT62 ED24 = 24" OAL
RT62 EDCCC36
Add WH for
(coiled cord)
white stem
Max 10 amps.
12"
9"
6"
6"
6"
9"
9"
"L" Joiner Block
"T" Joiner Block
RT62-LD
RT62-TD
Inline joiner block available: RT62ILD
CANDLEPOWER
ZONE
0
22
45
Deg.
180
763
763
763
175
758
762
776
165
739
814
916
155
681
841
942
145
601
809
929
135
474
690
848
125
368
582
796
115
221
429
566
105
89
236
320
95
14
71
99
90
0
47
57
85
0
28
38
75
0
12
25
65
0
4
19
55
0
2
7
45
0
0
3
35
0
0
1
25
0
0
0
15
0
0
0
5
0
0
0
0
0
0
0
ZONAL LUMEN SUMMARY
ZONE
LUMENS % BARELAMP % LUMINAIRE
0-90
91
1.6
90-180
3506
60.4
0-180
3597
62.0
8-FOOT JOINER
96" (243.84cm)
96" (243.84cm)
STEM OR CABLE
8-FOOT JOINER
12" (30.54cm)
18" (45.72cm)
24" (60.96cm)
Single Stem
Cable Assemblies
Chrome
C36 (cable only)
S12 = 12" OAL
CC36 (cable/straight
S18 = 18" OAL
cord feed)
S24 = 24" OAL
CCC36 (cable/coiled
Add WH for
cord feed)
white stem
12"
6"
6"
6"
9"
"X" Joiner Block
RT62-XD

Lighting Systems

67
90
763
763
794
800
970
978
1015
1035
50
1045
1078
0
59
999
1042
1
51
898
885
616
628
2
44
356
360
3
39
109
109
4
34
67
69
48
58
5
30
40
42
6
27
29
31
7
24
13
15
4
5
8
22
3
3
9
19
0
0
10
18
0
0
0
0
0
0
SPACING RATIOS: PARALLEL = 1.3 / PERPENDICULAR = 1.5
ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR
2.5
120
97.5
100
100.0
80
60
40
20
20
3
4
5
48" (121.92cm)
SINGLE
SINGLE
STEM OR CABLE
3" (7.62cm) END SET
4-FOOT JOINER
Ordering Instructions
Individual Fixtures:
1. Order number of JOINER FIXTURES.
2. Order one POWER FEED END SET per fixture.
3. Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE.
Continuous Rows:
1. Determine run length.
2. Order the appropriate number of JOINER FIXTURES for the complete run.
3. Order one POWER FEED END SET per run.
4. Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE.
5. For cable mounted runs that exceed amperage limits, order the appropriate
number of CABLE/CORD FEEDS.
Square/Rectangle Patterns:
1. Order appropriate number of JOINER FIXTURES to complete the pattern size.
2. Order number and type of JOINER BLOCKS required.
3. Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE.
4. For cable mounted patterns that exceed amperage limits, order the appropriate
number of CABLE/CORD FEEDS.
Job Information
We reserve the right to change details of design, materials and finish.
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
% WALL REFLECTANCE
30
10
50
30
10
50
59
59
41
51
51
35
49
47
44
42
40
30
41
38
38
35
33
26
35
31
33
30
27
23
30
26
29
26
23
20
26
22
26
22
19
18
22
19
23
19
16
16
19
16
21
17
14
14
17
14
19
15
12
13
15
12
17
13
11
12
14
11
15
12
9
11
2000 LUMENS PER LAMP
RCR = 1 (Rm. Width = 10xMtg. Ht. above work plane)
RCR = 5 (Rm. Width = 2xMtg. Ht. above work plane)
RCR = 10 (Rm. Width = Mtg. Ht. above work plane)
40
60
80
100
120
140
AREA PER FIXTURE IN SQUARE FEET
6
7
8
9
10
11
12
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
Dimensions given are both fixture
lengths and mounting distances.
Type:
RT6-5
50
30
10
35
35
29
28
25
23
21
19
18
16
16
14
13
12
12
10
10
09
09
08
08
07
160
13

Advertisement

loading
Need help?

Need help?

Do you have a question about the Lighting Systems RT6-5 and is the answer not in the manual?