to it final position. Once close to the final position, lift
the stove in to place. Sliding will definitely scratch the
floor.
CONNECTIONS:
cord, check all visible wire connections. Shipping and
general handling may have dislodged or broken a
connection.
The FUEL SENSOR is located on the bottom middle
of the stove. The sensor should be tight to the bottom
and the black wires connected. This sensor shuts
down the stove when you run out of fuel. This is a
convenience sensor.
The BURN BACK SENSOR is located on the down
chute at the feed end of the auger assembly. The
sensor should be tight to the surface and the
wires connected. This sensor will turn the auger on to
full speed if heat is sensed at the feed portion of the
auger tube. This sensor is active even if the stove is
turned off, as long as the power cord remains plugged
in to the receptacle.
The AUGER GEAR MOTOR should be securely
mounted and the
the set screw is tightened on the flat portion of the
shaft. The motor should rock from side to side freely.
When rotated full to the side opposite the control
board the housing should hit a bumper. The auger
wires carry 110 volts. DO NOT TOUCH the contacts
when the power cord is plugged in..