3-9. Mounting

(1) To install the indoor unit, mount the indoor unit onto
the 2 tabs on the upper part of the rear plate.
(2) Hold down the air discharge outlet and press the
lower part of the indoor unit until it clicks to secure-
ly fasten to the 2 tabs on the lower part of the rear
plate. (Fig. 33)
NOTE
For tubing, choose either the right or left tubing direc-
tion and follow the steps below. Also, extend the sup-
port on the back of the indoor unit as a stand to make
your work easier. (Fig. 34)
Right-side tubing
(1) Shape the refrigerant tubing so that it can easily go
into the wall hole. (Fig. 35)
(2) Push the wiring, refrigerant tubing, and drain hose
through the hole in the wall. Adjust the indoor unit
so it is securely seated on the rear panel. (Fig. 36)
(3) Carefully bend the tubing (if necessary) to run
along the wall in the direction of the outdoor unit
and then tape as far as the fittings. (See Caution
on page 17.) The drain hose should come straight
down the wall to a point where water runoff won't
stain the wall.
(4) Connect the refrigerant tubing to the outdoor unit.
(After performing a leak test on the connecting part,
insulate it with the tubing insulation (Fig. 37a)).
Also, refer to Section 5-4. Connecting Tubing
between Indoor and Outdoor Units.
(5) Assemble the refrigerant tubing, drain hose, and
conduit (including inter-unit wiring) as shown in
Fig. 37b.
Push
Rear panel
Cover
Insulation
Fig. 37a
13
Fig. 33
Stand
Fig. 34
Refrigerant
tubing
Inter-unit
wiring
Drain hose
Fig. 35
Fig. 36
Refrigerant tubing
Conduit
Drain hose
Inter-unit wiring
Fig. 37b