TECHNICAL DATA
12KHS32
FILE NO.
SPLIT SYSTEM AIR CONDITIONER
Indoor Model No.
Product Code No.
Outdoor Model No.
Product Code No.
KHS1232
1 852 658 14
CH1232
1 852 754 05
Indoor Unit
Outdoor Unit
CH1232
KHS1232
TD
701219
REFERENCE NO.
W

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo KHS1232

  • Page 1 TECHNICAL DATA 12KHS32 FILE NO. SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. KHS1232 1 852 658 14 CH1232 1 852 754 05 Indoor Unit Outdoor Unit CH1232 KHS1232 701219 REFERENCE NO.
  • Page 2 IMPORTANT! When Transporting Please Read Before Starting Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when This air conditioning system meets strict safety and operating lifting to reduce strain on your back. Sharp edges or thin alu- standards.
  • Page 3: Table Of Contents

    Table of Contents Page 1. OPERATING RANGE ........................2. SPECIFICATIONS........................3. DIMENSIONAL DATA ........................4. COOLING CAPACITY ........................5. HEATING CAPACITY ........................6. AIR THROW DISTANCE CHART ....................7. REFRIGERANT FLOW DIAGRAM ....................8. INSTALLATION INSTRUCTIONS ....................9. ELECTRICAL DATA ........................10.
  • Page 4: Operating Range

    1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95°F DB / 71°F WB 115°F DB Cooling Minimum 67°F DB / 57°F WB 67°F DB Maximum 80°F DB / 67°F WB 75°F DB / 65°F WB Heating Minimum —...
  • Page 5: Specifications

    2. SPECIFICATIONS 2-1. Unit Specifications Indoor unit KHS1232 Outdoor unit CH1232 Power Source 230 / 208V – Single phase – 60Hz Cooling Heating BTU/h 11,700 / 11,500 13,000 / 12,700 Capacity 3.43 / 3.37 3.81 / 3.72 Air circulation (High) / min.
  • Page 6 2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor unit KHS1232 Remote Control Unit RCS-KHS2422W POW-KHS1222-A Control circuit fuse AC 250V - 3A Switch Ass’y SW-KHS2412W AH-KH1212 Input (230 / 208V) 1.5 / 1.23 Protective thermostat OFF 140 ± 5°F, ON 122 ± 9°F Thermo fuse Cut-off 341 + 2, –5°F, 277V - 15A...
  • Page 7 2-2-2. Outdoor Unit Outdoor unit CH1232 POW-CH1232 Control circuit fuse AC 250V - 3A Type Rotary (hermetic) Model … Number C-R95H6E … 1 No. of cyl. … rpm 1 … 3,500 Nominal output Compressor lubricant Ω Coil resistance C – R: 1.89 (Ambient temp.
  • Page 8: Dimensional Data

    3. DIMENSIONAL DATA Indoor unit KHS1232 14-3/16 38-31/32 7-13/16 Rear panel (Center point of gravity) Wireless remote control unit 1-61/64 2-13/64 19/32 Drain hose O.D. 1-1/4 5-19/32 Center of Narrow tube O.D. 1/4 tubing hole (For right rear) Wide tube O.D. 1/2...
  • Page 9 Outdoor unit CH1232 4 × 15/32 dia. hole Air intake intake Check port Air discharge 1/4" narrow tubing 23-15/16 2-3/8 service valve 1/2" wide tubing 29-17/32 2-1/4 11-1/32 service valve Dimension: in.
  • Page 10: Cooling Capacity

    4. COOLING CAPACITY Indoor unit KHS1232 Outdoor unit CH1232 230V single phase 60Hz Rating Capacity: 11,700 BTU/h Air Flow Rate: 360 CFM Evaporator Condenser Ent. Temp. °F (°C) Ambient Temp. °F (°C) (23.9) (29.4) (35.0) (40.6) (46.1) 11,580 11,060 10,530...
  • Page 11 Indoor unit KHS1232 Outdoor unit CH1232 208V single phase 60Hz Rating Capacity: 11,500 BTU/h Air Flow Rate: 330 CFM Evaporator Condenser Ent. Temp. °F (°C) Ambient Temp. °F (°C) (23.9) (29.4) (35.0) (40.6) (46.1) 11,390 10,870 10,350 9,760 8,970 0.88 0.96...
  • Page 12: Heating Capacity

    5. HEATING CAPACITY Indoor unit KHS1232 Outdoor unit CH1232 Outdoor temperature (°F DB) NOTE … Point of rating condition Black dot in the chart indicates the following rating condition. Indoor : 70°F DB Outdoor : 47°F DB / 43°F WB 2) Above characteristics indicate instantaneous operation, which does not take into consideration defrost operation.
  • Page 13: Air Throw Distance Chart

    6. AIR THROW DISTANCE CHART Indoor unit KHS1232 Cooling 230V Room air temperature : 80°F Fan speed : High Horizontal distance (ft.) 0° 30° 208V Room air temperature : 80°F Fan speed : High Horizontal distance (ft.) 0° 30°...
  • Page 14 Indoor unit KHS1232 Heating 230V Room air temperature : 70°F Fan speed : High Horizontal distance (ft.) 45° 60° 208V Room air temperature : 70°F Fan speed : High Horizontal distance (ft.) 45° 60°...
  • Page 15: Refrigerant Flow Diagram

    7. REFRIGERANT FLOW DIAGRAM Indoor unit KHS1232 Outdoor unit CH1232 Indoor Unit Outdoor Unit Accumulator Wide tube service Wide tube valve 4-way Muffler valve O.D. 1/2" (12.7 mm) Narrow tube Check service Capillary tube port Narrow tube valve Capillary tube...
  • Page 16: Installation Instructions

    8. INSTALLATION INSTRUCTIONS 8-1. Installation Site Selection Indoor Unit To prevent abnormal heat WARNING generation and the possibility Indoor unit of fire, do not place obsta- cles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow.
  • Page 17 Outdoor Unit For stable operation of the air con- CAUTION ditioner, do not install wall-mount- AVOID: ed type indoor units under 4.9 ft. heat sources, exhaust fans, etc. (Fig. 4a) from the floor level. damp, humid or uneven locations. Indoor unit Wall choose a place as cool as possible.
  • Page 18 8-2. Remote Control Unit Installation Position Remote control unit The remote control unit can be operated from either a non-fixed position or a wall-mounted fixed position. Rear plate To ensure that the air conditioner operates correctly, do not install the remote control unit in the following places: Remote control unit mounting cradle in direct sunlight...
  • Page 19 Indoor Unit 2) Switch Positions for Up to 4 Units Table 2 shows the positions you can use for up to 4 indoor units installed in the same room. Table 2 Remote control unit Indoor unit Unit No. NOTE Address switch An indoor unit cannot be remote controlled if its remote (for receiving) control unit is too far away (more than 25 ft.).
  • Page 20 8-4. Recommended Wire Length and Size Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to NOTE your local electrical codes. Carefully observe these reg- Refer to the WIRING SYSTEM DIAGRAM for the ulations when carrying out the installation. meaning of “A”, “B”...
  • Page 21: Electrical Data

    9. ELECTRICAL DATA G Electrical Characteristics Indoor unit KHS1232 Outdoor unit CH1232 Cooling Indoor Unit Outdoor Unit Complete Unit Rating Condition Fan Motor Fan Motor Compressor (a+b+c) 0.18 0.42 230V Performance 1,083 1,210 at 60 Hz 0.17 0.39 5.34 Single phase...
  • Page 22: Electric Wiring Diagrams

    10. ELECTRIC WIRING DIAGRAMS Indoor unit KHS1232 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. Terminal plate Thermistor Transformer Noise filter SG-OUT CONTROLLER Heater relay H. Thermo H M L LL...
  • Page 23 Outdoor unit CH1232 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. Solenoid Connector coil Power transformer Noise filter Terminal plate Thermistor (coil) SEC TH1 Thermistor (air temp) SG-IN Thermistor (discharge) CONTROLLER Capacitor Power...
  • Page 24 For Parts or Service Contact SANYO FISHER SERVICE CORPORATION 1200 West Artesia Blvd., Compton, California, 90220, USA Oct. / ’95 / 1350 Printed in the U.S.A. 50 Beth Nealson Drive, Toronto, Ontario, M4H 1M6, CANADA...