To reset the control enter your user code the sounder will emit
a low level two tone alternating ( Dee dah ) sound to indicate that there is a
"RESET REQUIRED". Press the # key to reset the control. If the reset is
allowed an accept tone will be given the LEDs for the zones in alarm will go
out and the control will return to the 'DAY' mode. If the reset is not allowed
the "ENG" LED will be flashing and an error tone will be given, the LEDs will
still indicate the alarm state. Call your alarm company to complete the reset.
You will not be able to set your system again until a reset has been
completed.
NOTE. If an internal speaker is not fitted in your control panel then the tones
given are limited and may not relate to the above information. Contact your
Installer regarding the fitting of a 16 ohm extension speaker..
4.0 USER OPTIONS
4.1 CHANGING ZONES ON CHIME
Press the * key. The display will show any zones currently set to
chime. Press the key number of the zone you wish to change. If the zone
does not have chime programmed an error tone will be given. Press the * key
to finish.
4.2 AUTO TEST
Enter your four digit user code, the buzzer will emit a steady sound
and the exit time start. Press the * key followed by the 9 key. The exit buzzer
will stop and all LEDs will light. After the 10 Second LED test the internal
sounder, bell and strobe will each operate for 5 seconds the control will then
emit an accept tone and revert to the 'DAY' mode. You may end the test at
any time by pressing the * key.

4.3 CHANGING THE USER CODE

There are four separate user codes available.
1
Master user (all options available)
2
Second user (Cannot change master user code)
3
Set / Unset user (Cannot change any user codes)
4
Set only use r (Cannot change any user codes)
Enter your four digit user code, the buzzer will emit a steady sound
and the exit time will start. Press the * key followed by the 9 key, then press
the 1 key. The LEDs 1 to 4 will light if all user codes are available. If a user
code has not been allocated the LED of that number will not be on.
Press the number for the code to be changed (1 for master code). The
LEDs 1 to 4 will now show which user code is being altered. The LEDs 5 6 7
and Tamper will now come on to indicate a new 4 digit code is required. Enter
your new code. As you press each key one LED will go out. If your new code
is allowed an accept tone will be given. If the new code is barred an error
3